{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0KA20-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0KA20-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0KA20-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0KA20-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker for motor protection, 3RV2011-0KA20-ZX95, Class 10 trip, 0.2 kW at 230 V, 100 kA SCCR at 400 V, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"## Motor protection breaker with Class 10 trip and 100 kA SCCR The Siemens SIRIUS 3RV2011-0KA20-ZX95 is a motor-protection circuit breaker with a Class 10 trip characteristic, meaning it disconnects the motor within 10 seconds at 7.2× the thermal setting — fast enough to protect standard induction motors from locked-rotor heating. It is rated 0.2 kW at 230 V AC (1 hp at 460/480 V, 0.5 hp at 575/600 V) and carries a 100 kA short-circuit breaking capacity across the 240–690 V range, so it safely interrupts high-fault currents without cascading upstream. The main circuit connects via spring-loaded terminals; no screw tightening needed on the power side. The unit occupies 45 mm width on the rail, with 97 mm depth and 106 mm height.","metaTitle":"Siemens 3RV2011-0KA20-ZX95 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV2011-0KA20-ZX95 motor protection circuit breaker, Class 10 trip, 0.2 kW at 230 V, 100 kA SCCR at 400 V. Screw and snap-on DIN rail mounting. Current lifecycle. So","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"106 mm","Upwards":"50 mm","Forwards":"0 mm","at 500 V":"gL/gG 16 A","at 690 V":"gL/gG 16 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","Mounting Position":"any","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.2 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"1.25 A","at 500 V rated value":"100 kA","at 600 V rated value":"1.25 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"spring-loaded terminals","at 460/480 V rated value":"1 hp","at 575/600 V rated value":"0.5 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"1.25 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"1.25 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1.25 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (20 ... 12)","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"16 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.9 ... 1.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/77f5af745228a6adcbec425b2ff9f78e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=518952&mlfb=3RV2011-0KA20-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0KA20-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the difference between 3RV2011-0KA20-ZX95 and 3RV2011-0BA20?","answer":"The 3RV2011-0BA20 is a sibling in the same SIRIUS frame, sharing the same Class 10 trip and DIN-rail footprint, but the -ZX95 variant carries a different accessory or factory-set option. Both mount identically on 35 mm DIN rail; panel rewiring is not required to swap between them if the terminal arrangement is the same, but verify the specific accessory configuration before substitution."},{"question":"What is the depth of 3RV2011-0KA20-ZX95?","answer":"The depth is 97 mm."},{"question":"What is the width of 3RV2011-0KA20-ZX95?","answer":"The width is 45 mm."},{"question":"Will 3RV2011-0KA20-ZX95 drop into a panel specified around 3RV2011-0BA20 without rewiring?","answer":"Both share the same mounting footprint — screw and snap-on onto 35 mm DIN rail — and the same basic terminal arrangement, so physical fit is identical. No rewiring of the rail position is needed, but confirm that any accessory or factory-set option on the -ZX95 matches the -BA20's configuration before committing the BOM line."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0KA20-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0KA20-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}