{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1AA10-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1AA10-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1AA10-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1AA10-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-1AA10-0BA0, size S00, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw-type terminals, phase failure detection.","salesMarkdown":"It is a current-production part. Trip class is CLASS 10. Mounting position is any — vertical, horizontal, upside-down in a tight cabinet; the thermal-magnetic trip doesn't care about orientation. Clearance requirements: 50 mm upward, 50 mm downward, 30 mm to the side, zero forward or backward. Main circuit terminals are screw-type, accepting 2x (0.75 to 2.5 mm²) solid or stranded, or 2x 4 mm². The screwdriver shaft needs to be 5 to 6 mm diameter with a Pozidriv size 2 tip. Torque down to the M3 thread spec for the main contacts — no spring-cage surprises here. ## Environmental and operating limits Rated voltage span is 20 to 690 V, covering control circuits through 690 V motor feeds. Maximum switching frequency at AC-3 duty (motor starting) is 15 operations per hour. That's fine for a pump or conveyor that cycles a few times an hour; for a high-cycle application like a reversing table, you'd step up to a larger frame or a contactor-based starter.","metaTitle":"Siemens 3RV2011-1AA10-0BA0 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV2011-1AA10-0BA0 motor protection circuit breaker, size S00, Class 10 trip, 100 kA breaking capacity at 400 V. Screw terminals, phase failure detection. Current pr","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","title":"3RV2011-1AA10-0BA0","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 500 V":"gG 20 A","at 690 V":"gG 16 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","description":"Special type Circuit breaker size S00 for motor protection, CLASS 10 A-release 1.1...1.6 A N-release 21 A screw terminal Standard switching capacity Ambient temperature -50 °C 500 switching cycles","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-50 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.3 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 500 V rated value":"100 kA","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"500","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"1.6 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"500","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"1.6 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1.6 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"500","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"21 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.1 ... 1.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$45.72","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a3d4d11de9b763834b1116db3030078.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=420348&mlfb=3RV2011-1AA10-0BA0"},"ai":{"faq":[{"question":"What are the mounting dimensions and clearance requirements?","answer":"The breaker is 45 mm wide, 97 mm deep, and 97 mm tall. It mounts on 35 mm DIN rail per DIN EN 60715. Required clearances: 50 mm above, 50 mm below, 30 mm to the side; no clearance needed forward or backward."},{"question":"Will the 3RV2011-1AA10-0BA0 drop into a panel specified around the 3RV2011-0AA10 without rewiring?","answer":"Both are size S00 motor protection circuit breakers with the same DIN-rail footprint and screw-type terminals, so the physical swap is straightforward. However, the -1AA10-0BA0 variant includes phase failure detection and has different internal trip characteristics — verify the motor FLA and coordination study before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1AA10-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1AA10-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}