{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1AA15-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1AA15-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1AA15-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1AA15-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor-protection circuit breaker, 3RV2011-1AA15-ZW97, Trip Class 10, 100 kA breaking capacity at 400 V, phase-failure detection, screw and snap-on 35 mm DIN rail.","salesMarkdown":"## Motor-protection circuit breaker, 3RV2011-1AA15-ZW97 Trip Class 10 means it trips within 10 seconds at 7.2× rated current — the standard for protecting standard induction motors during locked-rotor starts. Breaking capacity is 100 kA at 400 V, 500 V, and 690 V — that is high enough to sit downstream of a transformer or a large bus without requiring a current-limiting upstream device in most industrial installations. Dimensions are 97 mm deep, 45 mm wide, 97 mm tall. Clearance: 50 mm above and below, 30 mm at the side — plan the enclosure depth to accommodate the 97 mm body plus wiring space. Main circuit terminals accept screw-type connections: 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) solid or stranded. Torque to M3 for the main contacts. Mounting position is any — vertical, horizontal, upside-down — no derating needed for orientation.","metaTitle":"Siemens 3RV2011-1AA15-ZW97 SIRIUS Motor Protection CB, Class","metaDescription":"Siemens SIRIUS 3RV2011-1AA15-ZW97 motor-protection circuit breaker. Trip Class 10, 100 kA breaking capacity at 400 V, phase-failure detection. Current lifecycle, sourced to order a","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","at 24 V":"1 A","at 60 V":"0.15 A","Forwards":"0 mm","at 120 V":"0.5 A","at 125 V":"0.5 A","at 230 V":"0.5 A","at 500 V":"gL/gG 20 A","at 690 V":"gL/gG 16 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 hp","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"1.6 A","at 500 V rated value":"100 kA","at 600 V rated value":"1.6 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at 460/480 V rated value":"1 hp","at 575/600 V rated value":"0.8 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"1.6 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"1.6 A","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1.6 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","Of The Auxiliary And Control Contacts":"M3","at AC in hot operating state per pole":"2.4 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","contact rating of auxiliary contacts according to UL":"C300 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"21 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.1 ... 1.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ffe4a580b3b429b87af5d28bac7dc6fe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=158933&mlfb=3RV2011-1AA15-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1AA15-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RV2011-1AA15-ZW97?","answer":"100 kA at 400 V, 500 V, and 690 V. That is the rated short-circuit breaking capacity — sufficient for most industrial panel applications without requiring an upstream current-limiting device."},{"question":"Will 3RV2011-1AA15-ZW97 fit a panel designed for 3RV2111-1AA10?","answer":"Both mount on 35 mm DIN rail and share the same 45 mm width and 97 mm depth, so the mechanical fit is identical. Terminal layout and wiring should be verified against the specific panel drawing, but the rail footprint and clearance requirements are the same."},{"question":"Where can I buy 3RV2011-1AA15-ZW97 and get current pricing?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1AA15-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1AA15-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}