{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1AA25-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1AA25-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1AA25-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1AA25-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2011-1AA25-ZX95, motor protection circuit breaker, Class 10, 100 kA breaking capacity at 400 V, screw and snap-on mounting onto 35 mm DIN rail, spring-loaded terminals.","salesMarkdown":"The spring-loaded terminals on the main circuit accept 2x (0.5...2.5 mm²) solid or stranded wire, which is the standard range for control wiring in this class. At 45 mm wide and 97 mm deep, it occupies a single 45 mm slot on the DIN rail. Required clearances: 50 mm above and below, 30 mm to the side, and 0 mm forward/backward — meaning it can be packed tight against the back panel or enclosure door. The auxiliary contact block handles 1 A at 24 V, 0.5 A at 120/125/230 V, and 0.15 A at 60 V. These are the standard signal-level ratings for feeding a PLC input or a contactor coil — not for power switching.","metaTitle":"Siemens 3RV2011-1AA25-ZX95 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-1AA25-ZX95 SIRIUS motor protection circuit breaker. Class 10 trip, 100 kA breaking capacity at 400 V, screw/snap-on DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"106 mm","Upwards":"50 mm","at 24 V":"1 A","at 60 V":"0.15 A","Forwards":"0 mm","at 120 V":"0.5 A","at 125 V":"0.5 A","at 230 V":"0.5 A","at 500 V":"gL/gG 20 A","at 690 V":"gL/gG 16 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 hp","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"1.6 A","at 500 V rated value":"100 kA","at 600 V rated value":"1.6 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"spring-loaded terminals","at 460/480 V rated value":"1 hp","at 575/600 V rated value":"0.8 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"1.6 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"1.6 A","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1.6 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (20 ... 12)","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","for AWG cables for auxiliary contacts":"2x (20 ... 14)","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","Finely Stranded Without Core End Processing":"2x (0.5 ... 1.5 mm²)","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","contact rating of auxiliary contacts according to UL":"C300 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"21 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.1 ... 1.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f2fbae1e60ded9bfa3c42a0b3a4f39ba.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604021&mlfb=3RV2011-1AA25-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1AA25-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this circuit breaker?","answer":"It has a 100 kA breaking capacity at 400 V and also at 690 V, which is a high-interrupting rating suitable for most industrial distribution panels without requiring upstream current-limiting fuses."},{"question":"How do I get current pricing and availability for 3RV2011-1AA25-ZX95?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to get current pricing and availability confirmed at quote time."},{"question":"What are the mounting dimensions for this part?","answer":"Width is 45 mm, depth is 97 mm, and height is 106 mm. It mounts on 35 mm DIN rail per DIN EN 60715, with required clearances of 50 mm above and below, and 30 mm to the sides."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1AA25-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1AA25-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}