{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1BA20-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1BA20-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1BA20-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1BA20-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-1BA20-ZW97, CLASS 10 trip, 100 kA SCCR at 400 V, 45 mm wide, spring-loaded terminals, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"## Motor protection circuit breaker — CLASS 10, 100 kA SCCR, spring-loaded terminals Rated short-circuit breaking capacity hits 100 kA at 240 V, 400 V, and 500 V AC, and 10 kA at 690 V AC — so it safely interrupts fault currents up to those levels without cascading upstream, which is critical for panel SCCR compliance per UL 508A. Spring-loaded terminals on the main circuit accept 2x (0.5... 4 mm²) solid or stranded wire, and the breaker mounts via screw and snap-on onto a 35 mm DIN rail per DIN EN 60715, in any mounting position. Dimensions are 45 mm wide, 106 mm tall, 97 mm deep — a standard 45 mm module that fits a typical 600 mm wide enclosure with room for side-by-side breakers; clearance requirements are 50 mm upwards and downwards, 30 mm to the side, and 0 mm forwards or backwards. ## Sourcing and lifecycle — current production, quoted to order ## Integration — DIN rail, spring terminals, clearance Snap the breaker onto a 35 mm DIN rail per DIN EN 60715; the spring-loaded terminals accept 2x (0.5... 4 mm²) wire. No forward or backward clearance needed, but allow 50 mm above and below, and 30 mm to the side for heat dissipation and wiring access.","metaTitle":"Siemens 3RV2011-1BA20-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV2011-1BA20-ZW97 motor protection circuit breaker, CLASS 10 trip, 100 kA SCCR at 400 V, 45 mm wide, spring-loaded terminals. Current production. Sourced to order a","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"106 mm","Upwards":"50 mm","Forwards":"0 mm","at 400 V":"gL/gG 25 A","at 500 V":"gL/gG 25 A","at 690 V":"gL/gG 20 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","Mounting Position":"any","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.13 hp","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"2 A","at 500 V rated value":"100 kA","at 600 V rated value":"2 A","at 690 V rated value":"10 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"spring-loaded terminals","at 460/480 V rated value":"1 hp","at 575/600 V rated value":"1 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"10 kA","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"2 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"2 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"2 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (20 ... 12)","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"26 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.4 ... 2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=279217&mlfb=3RV2011-1BA20-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1BA20-ZW97/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV2011-1BA20-ZW97 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is 3RV2011-1BA20-ZW97's listed depth?","answer":"The depth is 97 mm."},{"question":"What is 3RV2011-1BA20-ZW97's listed width?","answer":"The width is 45 mm."},{"question":"Will 3RV2011-1BA20-ZW97 drop into a panel specified around 3RV1011-0GA10 without rewiring?","answer":"Both are SIRIUS motor protection breakers on a 45 mm footprint with spring-loaded terminals, so the physical fit and wiring are the same — but the 3RV2011-1BA20-ZW97 has a CLASS 10 trip and 100 kA SCCR at 400 V, while the 3RV1011-0GA10 has a different trip class and lower SCCR; verify the trip curve and fault rating against your motor data before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1BA20-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1BA20-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}