{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1DA10-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1DA10-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1DA10-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1DA10-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-1DA10-ZX95, CLASS 10 trip class, 100 kA SCCR at 400 V, 97 x 45 x 97 mm, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"## Motor protection circuit breaker, CLASS 10, 100 kA SCCR Panel cutout is 45 mm wide, 97 mm tall, and the body depth is 97 mm — standard for the SIRIUS 3RV2 frame. Any mounting position allowed, so it fits tight enclosures or horizontal bus layouts. ## Clearance and integration Minimum clearances to adjacent components: 50 mm upwards, 50 mm downwards, 30 mm to the side. Zero clearance required forwards or backwards — the breaker can be mounted flush against a panel backplate or enclosure wall. Ambient operating range -20 to +60 °C with temperature compensation active across the same span. Storage and transport range -50 to +80 °C. The breaker derates above 40 °C per the thermal curve; the compensation keeps the trip curve accurate across the operating band.","metaTitle":"Siemens 3RV2011-1DA10-ZX95 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV2011-1DA10-ZX95 motor protection circuit breaker, CLASS 10 trip, 100 kA SCCR at 400 V, 97x45x97 mm, screw/snap-on DIN rail. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 400 V":"gL/gG 25 A","at 500 V":"gL/gG 32 A","at 690 V":"gL/gG 25 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.25 hp","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"3.2 A","at 500 V rated value":"100 kA","at 600 V rated value":"3.2 A","at 690 V rated value":"10 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at 110/120 V rated value":"0.1 hp","at 200/208 V rated value":"0.5 hp","at 220/230 V rated value":"0.75 hp","at 460/480 V rated value":"2 hp","at 575/600 V rated value":"2 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"10 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"3.2 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"3.2 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"42 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.2 ... 3.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=467847&mlfb=3RV2011-1DA10-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1DA10-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV2011-1DA10-ZX95 and get a price?","answer":"Sourced through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time, no stock or price figures held on this listing."},{"question":"What are the key ratings for 3RV2011-1DA10-ZX95?","answer":"CLASS 10 trip class, 100 kA SCCR at 400 V, rated voltage 20–690 V AC, motor protection design with phase failure detection, screw-type terminals accepting 2x 0.75–2.5 mm² or 1x 4 mm², dimensions 97 x 45 x 97 mm, snap-on or screw mount on 35 mm DIN rail."},{"question":"Will 3RV2011-1DA10-ZX95 drop into a panel specified around 3RV2011-0AA10?","answer":"The 3RV2011-1DA10-ZX95 shares the same 45 mm width and 97 mm height as the 3RV2011-0AA10 frame, and both mount on 35 mm DIN rail per EN 60715. Terminal layout and screw-type connections are identical. It should fit the same panel cutout and rail position without rewiring, but verify the trip setting range and SCCR rating on the nameplate against your BOM — the -ZX95 suffix may carry a different factory-set current range or special version marking."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1DA10-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1DA10-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}