{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1EA15-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1EA15-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1EA15-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1EA15-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-1EA15-0BA0, Trip Class 10, 100 kA breaking capacity at 400 V AC, 45 mm width, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"At 690 V AC the breaking capacity drops to 4 kA, so verify your system voltage against the rating table. Rated motor power is 0.8 kW at 230 V. The auxiliary contacts handle 1 A at 24 V and 0.5 A at 230 V — enough to signal a PLC input or drop out a contactor coil. ## Panel integration At 45 mm wide and 97 mm deep, it takes one standard DIN module slot. The screw-type terminals on the main circuit accept 2×(0.5…1.5 mm²) solid or stranded.","metaTitle":"Siemens 3RV2011-1EA15-0BA0 SIRIUS Motor Protection CB, Class","metaDescription":"Siemens SIRIUS 3RV2011-1EA15-0BA0 motor protection circuit breaker, Trip Class 10, 100 kA breaking capacity at 400 V AC, 45 mm wide, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","at 24 V":"1 A","at 60 V":"0.15 A","Forwards":"0 mm","at 120 V":"0.5 A","at 125 V":"0.5 A","at 230 V":"0.5 A","at 400 V":"gG 32 A","at 500 V":"gG 32 A","at 690 V":"gG 25 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-50 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.8 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 500 V rated value":"100 kA","at 690 V rated value":"4 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"500","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"4 A","Of Auxiliary Contacts Typical":"500","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"4 A","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","Of The Auxiliary And Control Contacts":"M3","at AC in hot operating state per pole":"2.4 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"500","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"52 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.8 ... 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2623351bc7abb8f9685fff800f381336.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=521003&mlfb=3RV2011-1EA15-0BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1EA15-0BA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV2011-1EA15-0BA0?","answer":"This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — stock levels and lead time are confirmed at quote time."},{"question":"What is the closest functional alternative to 3RV2011-1EA15-0BA0?","answer":"The 3RV2021-1FA15 is a physically similar SIRIUS motor protection breaker but carries different thermal setting ranges and breaking capacities. Verify your motor full-load current and available fault current against the 3RV2021-1FA15 datasheet before substituting — the 3RV2011-1EA15-0BA0 remains the direct fit for the original BOM line."},{"question":"Will 3RV2011-1EA15-0BA0 drop into a panel wired for 3RV2021-1FA15?","answer":"Both mount on 35 mm DIN rail and share the same 45 mm width footprint, so mechanical fit is identical. However, the terminal layout and auxiliary contact configuration may differ — confirm wiring before swapping without a panel recheck."},{"question":"What are the key specs of 3RV2011-1EA15-0BA0?","answer":"Trip Class 10, 100 kA breaking capacity at 400 V AC, 0.8 kW motor rating at 230 V, phase failure detection, 45 mm wide, 97 mm deep, screw-type terminals, DIN rail mount."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1EA15-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1EA15-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}