{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1EA25-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1EA25-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1EA25-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1EA25-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-1EA25-ZW97, Class 10 trip, 100 kA breaking capacity at 400 V, spring-loaded terminals, screw and snap-on 35 mm DIN rail.","salesMarkdown":"The spring-loaded terminals accept 2x (0.5... 2.5 mm²) solid or stranded wire, which saves panel wiring time compared to screw terminals. This is a current-production part. ## DIN rail fit and spacing The 3RV2011-1EA25-ZW97 measures 45 mm wide, 106 mm tall, and 97 mm deep. That 45 mm width is three standard 15 mm module slots on a DIN rail — a common footprint for a motor protection breaker in this class. For side-by-side mounting, the minimum clearance to adjacent devices is 30 mm at the side, 50 mm upwards, and 50 mm downwards. Zero clearance forwards and backwards means it can sit flush against a back panel or enclosure wall. At 690 V the capacity drops to 4 kA — still sufficient for most 690 V motor circuits in industrial plants, but worth noting if the fault current at that voltage exceeds 4 kA. For comparison, the 3RV1011-1HA10 carries a lower 55 kA at 400 V, so the 3RV2011-1EA25-ZW97 offers more headroom in high-fault installations without an upstream current-limiting device. ## Environmental limits The auxiliary contact ratings cover 24 V at 1 A, 60 V at 0.15 A, 120 V at 0.5 A, 125 V at 0.5 A, and 230 V at 0.5 A — useful for feeding a PLC input or a status lamp.","metaTitle":"Siemens 3RV2011-1EA25-ZW97 SIRIUS Motor Protection CB, 100 k","metaDescription":"Siemens SIRIUS 3RV2011-1EA25-ZW97 motor protection circuit breaker, Class 10, 100 kA breaking capacity at 400 V, spring terminals, DIN rail. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"106 mm","Upwards":"50 mm","at 24 V":"1 A","at 60 V":"0.15 A","Forwards":"0 mm","at 120 V":"0.5 A","at 125 V":"0.5 A","at 230 V":"0.5 A","at 400 V":"gL/gG 32 A","at 500 V":"gL/gG 32 A","at 690 V":"gL/gG 25 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.33 hp","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"4 A","at 500 V rated value":"100 kA","at 600 V rated value":"4 A","at 690 V rated value":"4 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","at 110/120 V rated value":"0.13 hp","at 200/208 V rated value":"0.8 hp","at 220/230 V rated value":"0.75 hp","at 460/480 V rated value":"2 hp","at 575/600 V rated value":"3 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"4 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"4 A","at AWG cables for main contacts":"2x (20 ... 12)","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 14)","at AC in hot operating state per pole":"2.4 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","Finely Stranded Without Core End Processing":"2x (0.5 ... 1.5 mm²)","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","contact rating of auxiliary contacts according to UL":"C300 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"52 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.8 ... 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f49e641efbcc1c79b7eb98073fdf384f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=622687&mlfb=3RV2011-1EA25-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1EA25-ZW97/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV2011-1EA25-ZW97 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is 3RV2011-1EA25-ZW97's listed depth (97 mm) on this component line?","answer":"The depth is 97 mm. That measurement includes the body and the spring-loaded terminal protrusion — account for it when sizing the enclosure depth."},{"question":"What is 3RV2011-1EA25-ZW97's listed width (45 mm) on this component line?","answer":"The width is 45 mm, which occupies three 15 mm DIN-rail module slots. Side clearance of 30 mm to adjacent devices is required."},{"question":"Will 3RV2011-1EA25-ZW97 drop into a panel that was specified around 3RV1011-1HA10 without rewiring?","answer":"Both mount on 35 mm DIN rail per DIN EN 60715 and share the same 45 mm width and spring-terminal wiring range. The 3RV2011-1EA25-ZW97 is a direct mechanical and electrical swap for the 3RV1011-1HA10 in most panels, with the advantage of a higher 100 kA breaking capacity at 400 V versus 55 kA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1EA25-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1EA25-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}