{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1EA25-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1EA25-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1EA25-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1EA25-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2011-1EA25-ZX95 motor protection circuit breaker, Trip Class 10, 100 kA breaking capacity at 400 V, phase failure detection, screw and snap-on 35 mm DIN rail mount, spring-loaded terminals.","salesMarkdown":"## Motor protection circuit breaker for the mill floor The Siemens 3RV2011-1EA25-ZX95 is a SIRIUS motor protection circuit breaker designed for motor protection duty, with Trip Class 10 and phase failure detection. It mounts on 35 mm DIN rail per DIN EN 60715 via screw or snap-on, and accepts spring-loaded terminals for the main circuit. The 100 kA breaking capacity at 400 V gives you headroom for high-fault-current panels — keeps the machine running when a motor winding shorts. ## Mounting and integration Fastens with screw or snaps onto 35 mm DIN rail per DIN EN 60715; mounting position is any. Dimensions are 97 mm deep, 45 mm wide, 106 mm high — fits a standard 45 mm slot in a motor control center. Clearance required: 50 mm upward, 50 mm downward, 30 mm at the side. Spring-loaded terminals accept 2x (0.5... 2.5 mm²) solid or stranded. ## Breaking capacity and coordination Rated breaking capacity at 240 V, 400 V, and 500 V is 100 kA; at 690 V it drops to 4 kA. That 100 kA at 400 V means this breaker can safely interrupt a bolted fault up to that level without cascading upstream — critical for selectivity in a distribution panel. The gL/gG fuse backup ratings at 400 V and 500 V are 32 A, at 690 V it's 25 A.","metaTitle":"Siemens 3RV2011-1EA25-ZX95 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-1EA25-ZX95 SIRIUS motor protection circuit breaker. Trip Class 10, 100 kA breaking capacity at 400 V, phase failure detection. Screw and snap-on DIN rail mount. Ava","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"106 mm","Upwards":"50 mm","at 24 V":"1 A","at 60 V":"0.15 A","Forwards":"0 mm","at 120 V":"0.5 A","at 125 V":"0.5 A","at 230 V":"0.5 A","at 400 V":"gL/gG 32 A","at 500 V":"gL/gG 32 A","at 690 V":"gL/gG 25 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.33 hp","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"4 A","at 500 V rated value":"100 kA","at 600 V rated value":"4 A","at 690 V rated value":"4 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"spring-loaded terminals","at 110/120 V rated value":"0.13 hp","at 200/208 V rated value":"0.8 hp","at 220/230 V rated value":"0.75 hp","at 460/480 V rated value":"2 hp","at 575/600 V rated value":"3 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"4 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"4 A","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"4 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (20 ... 12)","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","for AWG cables for auxiliary contacts":"2x (20 ... 14)","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","Finely Stranded Without Core End Processing":"2x (0.5 ... 1.5 mm²)","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","contact rating of auxiliary contacts according to UL":"C300 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"52 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.8 ... 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1a0ff3260831ec6e11a12804930d4ac1.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604023&mlfb=3RV2011-1EA25-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1EA25-ZX95/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RV2011-1EA25-ZX95?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional second-source to 3RV2011-1EA25-ZX95?","answer":"The 3RV2021-1FA15 is a peer from the same SIRIUS family, but the 3RV2011-1EA25-ZX95 has a 45 mm width versus the 3RV2021-1FA15's wider footprint, so panel drop-in depends on the existing DIN rail slot width."},{"question":"What is 3RV2011-1EA25-ZX95's listed depth?","answer":"97 mm."},{"question":"What is 3RV2011-1EA25-ZX95's listed width?","answer":"45 mm."},{"question":"Will 3RV2011-1EA25-ZX95 drop into a panel specified around 3RV2021-1FA15 without rewiring?","answer":"The 3RV2011-1EA25-ZX95 is 45 mm wide, while the 3RV2021-1FA15 uses a wider footprint; check the DIN rail slot width before assuming a direct swap. Both use spring-loaded terminals, so wiring may transfer if the slot fits."},{"question":"What compliance documentation does Siemens provide for 3RV2011-1EA25-ZX95?","answer":"The evidence does not list specific compliance documents (RoHS, REACH, UL, IEC) for this order code. Standard Siemens SIRIUS documentation typically covers these, but verify with the datasheet or your Siemens contact."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1EA25-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1EA25-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}