{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1FA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1FA10","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1FA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1FA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2011-1FA10 motor protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 400 V, 45 x 97 x 97 mm, screw and snap-on DIN rail mount.","salesMarkdown":"## Motor protection with Class 10 trip response The 3RV2011-1FA10: Built-in phase failure detection ensures the breaker trips if one phase drops out, preventing single-phasing damage to the motor winding. This is a standard feature on this SIRIUS generation — not an add-on module. ## Breaking capacity and fault coordination This lets the panel designer coordinate upstream fuses with the breaker's let-through energy for selective coordination. ## Panel fit and DIN rail mounting The screw and snap-on fastening method lets you clip it onto the rail without tools for initial placement, then secure with the screw for vibration resistance. Dimensions are 97 mm deep by 97 mm tall. The required clearance around the breaker: 50 mm above and below, 30 mm to the sides, and zero clearance forward or backward. This matters when laying out a densely populated panel — the side clearance is tighter than some competing frames. The main contact screw size is M3.","metaTitle":"Siemens 3RV2011-1FA10 SIRIUS Motor Protection Circuit","metaDescription":"Siemens 3RV2011-1FA10 SIRIUS motor protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 400 V, 45 mm wide, DIN rail mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","title":"3RV2011-1FA10","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 400 V":"gL/gG 32 A","at 500 V":"gL/gG 32 A","at 690 V":"gL/gG 25 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for motor protection, CLASS 10 A-release 3.5...5 A N release 65 A screw terminal Standard switching capacity","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.5 hp","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"5 A","at 500 V rated value":"100 kA","at 600 V rated value":"5 A","at 690 V rated value":"4 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.17 hp","at 200/208 V rated value":"1 hp","at 220/230 V rated value":"1 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"3 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"5 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"5 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"5 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"65 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"3.5 ... 5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$40.64","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/536512cd8a2d2c4f3d3482c5848dd1d0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=473223&mlfb=3RV2011-1FA10"},"ai":{"faq":[{"question":"What is the breaking capacity of the 3RV2011-1FA10 at 400 V?","answer":"100 kA at 400 V. The same 100 kA rating applies at 240 V and 500 V. At 690 V the rating is 4 kA."},{"question":"Will the 3RV2011-1FA10 drop into a panel designed for the 3RV2021-1FA15?","answer":"The 3RV2011-1FA10 is a 45 mm wide SIRIUS frame, same as the 3RV2021-1FA15. The physical footprint and mounting are the same — it will drop into the same DIN slot without panel modification. Verify the electrical ratings match your application, as the 3RV2021-1FA15 may have different trip ranges or breaking capacities."},{"question":"How can I order the 3RV2011-1FA10 or check availability?","answer":"This part is sourced through independent distribution channels. No stock-holding claim is made on this page."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1FA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1FA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}