{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1GA15-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1GA15-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1GA15-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1GA15-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2011-1GA15-0BA0, motor protection circuit breaker, Class 10, 100 kA breaking capacity at 400 V AC, screw-type terminals, snap-on mounting on 35 mm DIN rail.","salesMarkdown":"## What it is and what it does The Siemens SIRIUS 3RV2011-1GA15-0BA0 is a motor protection circuit breaker designed to protect three-phase motors against overload and short-circuit. It is rated for motor protection (Class 10 trip curve) and includes phase failure detection, so it will trip if one phase drops out — a common failure mode that can single-phase a motor and burn it out. Breaking capacity is 100 kA at 400 V AC, which means it can safely interrupt a fault current up to that level without cascading upstream — typical for industrial panel feeders where available fault current is high. At 690 V AC the rating drops to 4 kA, so verify the available fault current at your supply voltage. ## Mounting and integration Fastens with screws or snaps onto a 35 mm standard mounting rail per DIN EN 60715. Dimensions are 97 mm deep, 45 mm wide, 97 mm high — a compact footprint that fits a standard 45 mm-wide DIN slot. Mounting position is any, so it works in horizontal or vertical panel layouts. Clearance: 50 mm upwards and downwards, 30 mm to the side — enough for wiring access and heat dissipation. Screw-type terminals on the main circuit accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire. The terminal screw size is M3.","metaTitle":"Siemens 3RV2011-1GA15-0BA0 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV2011-1GA15-0BA0 motor protection circuit breaker, Class 10, 100 kA breaking capacity at 400 V AC. Screw terminals, snap-on DIN rail. Available to order; request q","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","at 24 V":"1 A","at 60 V":"0.15 A","Forwards":"0 mm","at 120 V":"0.5 A","at 125 V":"0.5 A","at 230 V":"0.5 A","at 400 V":"gG 50 A","at 500 V":"gG 40 A","at 690 V":"gG 35 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-50 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"1.5 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 500 V rated value":"100 kA","at 690 V rated value":"4 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"500","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"6.3 A","Of Auxiliary Contacts Typical":"500","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"6.3 A","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","Of The Auxiliary And Control Contacts":"M3","at AC in hot operating state per pole":"2.4 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"500","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"82 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"4.5 ... 6.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5c778fa06897271198e2cc455154d7bd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=616412&mlfb=3RV2011-1GA15-0BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1GA15-0BA0/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to 3RV2011-1GA15-0BA0?","answer":"The closest peer within the same SIRIUS family is 3RV2021-1GA15. Both are motor-protection breakers with Class 10 trip and screw terminals, but the 3RV2021 series uses a different frame size — verify panel cutout and mounting rail compatibility before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1GA15-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1GA15-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}