{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1GA25-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1GA25-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1GA25-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1GA25-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2011-1GA25-ZW96 motor protection circuit breaker, 6.3 A rated current at 480/600 V, 100 kA breaking capacity at 400 V, Trip Class 10, spring-loaded terminals, 45 mm wide.","salesMarkdown":"## Motor protection circuit breaker, SIRIUS, 6.3 A, 100 kA It carries a rated current of 6.3 A at both 480 V and 600 V, with a massive 100 kA breaking capacity at 400 V — meaning it can safely interrupt fault currents up to that level without cascading damage upstream in the panel. At 45 mm wide, it fits standard 45 mm slot spacing in most motor control centers. Depth is 97 mm, height 106 mm. Clearance requirements: 50 mm upward, 50 mm downward, 30 mm at the side, and 0 mm forward/backward — meaning you can pack it tight front-to-back, but leave breathing room above and below. Spring-loaded terminals on the main circuit accept 2× (0.5 to 2.5 mm²) solid or stranded conductors. No screw torque to verify — just strip, insert, and latch. ## Short-circuit and auxiliary contact ratings Short-circuit breaking capacity varies with voltage: 100 kA at 240 V, 400 V, and 500 V; 4 kA at 690 V. At 400 V and 500 V, the rating assumes upstream gL/gG fuses sized at 50 A and 40 A respectively; at 690 V, a 35 A gL/gG fuse is required. Auxiliary contact (integrated into the ZW96 variant) switches: 1 A at 24 V, 0.15 A at 60 V, 0.5 A at 120/125/230 V. These are the dry-contact ratings for the signal circuit — the 0.5 A at 120 V is typical for PLC input modules. The product lifecycle stage is current — meaning this is an active, in-production catalog item, not a phase-out or NRND part. No last-time-buy concerns; it's a standard BOM line.","metaTitle":"Siemens 3RV2011-1GA25-ZW96 SIRIUS Circuit Breaker, 6.3 A, 10","metaDescription":"Siemens SIRIUS 3RV2011-1GA25-ZW96 motor protection circuit breaker. 6.3 A rated current, 100 kA breaking capacity at 400 V. Trip Class 10. Spring-loaded terminals. Active productio","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"106 mm","Trip Class":"CLASS 10","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/709cac837a148652c7873ba69809a49c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=622688&mlfb=3RV2011-1GA25-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1GA25-ZW96/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1GA25-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1GA25-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}