{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1HA10-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1HA10-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1HA10-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1HA10-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, motor protection circuit breaker, 3RV2011-1HA10-0BA0, frame size S00, 100 kA interrupting capacity at 400 V AC, Class 10 trip, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"## What it is and what it does The Siemens SIRIUS 3RV2011-1HA10-0BA0 is a motor protection circuit breaker in the compact S00 frame size, designed to protect motors against overload, short-circuit, and phase failure. It snaps onto a 35 mm DIN rail (per DIN EN 60715) and terminates via screw-type terminals, making it a straightforward swap in existing panels. Its Class 10 trip characteristic means it will disconnect a locked-rotor motor fast enough to protect most standard induction motors, but not so fast that it nuisance-trips on normal starting inrush. The interrupting capacity is 100 kA at 400 V AC — that's the fault current it can safely clear without blowing apart, which covers the vast majority of industrial panel bus ratings. Phase failure detection is built in, so if a motor loses a phase upstream the breaker trips, preventing single-phasing damage. No ground fault detection here — that's separate if your application needs it. ## Panel fit and mounting S00 frame is 45 mm wide on the DIN rail. Depth is 97 mm. Mounting position is any orientation. Clearance requirements: 50 mm above and below, 30 mm to the side, zero forward or backward. That's the air gap needed for arc quenching and heat dissipation. If you're packing multiple breakers side-by-side, respect those numbers or the interrupting capacity derates. Terminals accept up to 2x 4 mm² solid/stranded, or 2x 2.5 mm² ferruled. Use a Pozidriv size 2 screwdriver with a 5–6 mm shaft diameter. The screw-type terminals are robust for panel wiring but take a little longer than spring-cage — plan your wiring schedule accordingly.","metaTitle":"Siemens SIRIUS 3RV2011-1HA10-0BA0 Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV2011-1HA10-0BA0 motor protection circuit breaker, frame size S00, 100 kA interrupting capacity at 400 V AC, Class 10 trip. Current lifecycle. Quoted to order agai","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 400 V":"gG 50 A","at 500 V":"gG 40 A","at 690 V":"gG 35 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-50 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"1.5 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 500 V rated value":"42 kA","at 690 V rated value":"4 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"42 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"500","at AC in hot operating state":"9.25 W","at AC-3 at 400 V rated value":"8 A","Of Auxiliary Contacts Typical":"500","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"8 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"3.1 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"500","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"104 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"5.5 ... 8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0b88b6268f80bba5582f9e15d6fc1f39.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=460132&mlfb=3RV2011-1HA10-0BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1HA10-0BA0/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to the 3RV2011-1HA10-0BA0?","answer":"The 3RV2011-0AA10 is the same S00 frame, Class 10, and 100 kA interrupting capacity. The key difference is the overload setting range — verify the dial range on your existing unit before swapping. If the ranges match, it drops in without rewiring."},{"question":"What are the mounting clearances for the 3RV2011-1HA10-0BA0?","answer":"Clearances: 50 mm above and below, 30 mm to the side, zero forward or backward. These are the minimum air gaps for arc quenching and heat dissipation — ignore them and the interrupting capacity derates."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1HA10-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1HA10-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}