{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1HA15-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1HA15-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1HA15-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1HA15-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-1HA15-0BA0, Class 10 trip, 100 kA SCCR at 400 V, screw and snap-on DIN rail mounting.","salesMarkdown":"It's designed for motor protection, with phase failure detection built in, and it trips on a Class 10 curve, meaning it disconnects fast enough to protect a standard induction motor during a stall or locked-rotor event. Rated voltage spans 20 to 690 V, so it covers everything from 24 V control transformers up to 690 V industrial mains. Mounts on a standard 35 mm DIN rail (screw and snap-on per DIN EN 60715), and the terminals are screw-type, accepting 2x 0.5 to 2.5 mm² solid or stranded. No special tools — just a screwdriver and a rail. That means you can butt it against a backplate or a busbar cover without derating. The auxiliary contact ratings are worth noting if you're using it for status feedback: 1 A at 24 V, 0.5 A at 120/125/230 V, and only 0.15 A at 60 V. That's a standard signal contact — don't try to switch a contactor coil directly with it; use a separate relay for that. For backup fusing, the manufacturer specifies gG cartridge fuses: 50 A at 400 V, 40 A at 500 V, 35 A at 690 V. That's the coordinated short-circuit protection for the breaker itself — if you're building a UL 508A panel, those values will drive your SCCR calculation. The closest sibling in the SIRIUS family is the 3RV2021-1GA15. Both are motor protection breakers with Class 10 trip curves and the same 45 mm width. The 3RV2021-1GA15 carries higher continuous current ratings — it's the next size up in the same form factor. If your motor FLA is above the 3RV2011's range, the 3RV2021 is the drop-in replacement on the same DIN rail footprint. No rewiring needed; same terminal pattern, same clearance zones.","metaTitle":"Siemens 3RV2011-1HA15-0BA0 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-1HA15-0BA0 SIRIUS motor protection circuit breaker. 100 kA SCCR at 400 V, Class 10 trip, screw & snap-on DIN rail. Sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Trip Class":"CLASS 10","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/905285f90416eb28ca975ee174f35a27.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=499861&mlfb=3RV2011-1HA15-0BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1HA15-0BA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1HA15-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1HA15-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}