{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1JA10-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1JA10-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1JA10-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1JA10-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2011-1JA10-ZW97 motor protection circuit breaker, Class 10, 100 kA breaking capacity at 400 V, 45 mm width, screw-type terminals.","salesMarkdown":"The Siemens 3RV2011-1JA10-ZW97 is a SIRIUS motor protection circuit breaker designed for motor protection, with a Trip Class 10 rating and a breaking capacity of 100 kA at 400 V rated value. Class 10 trip means the overload relay will open within 10 seconds at 600% of the set current, which protects standard induction motors during locked-rotor conditions without nuisance tripping on normal starting inrush. The 100 kA breaking capacity at 400 V ensures the device can safely interrupt fault currents up to that level without upstream cascading, per IEC 60947-2 requirements for motor protection. Mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715, with a width of 45 mm and depth of 97 mm, fitting standard motor control center (MCC) or panel layouts. Mounting position is any orientation, and the required clearances are 50 mm upward, 50 mm downward, 30 mm at the side, and 0 mm forward/backward — useful when packing breakers tightly in a panel. Screw-type terminals on the main current circuit accept 2x (0.75 to 2.5 mm²) solid or stranded, or 2x 4 mm², with M3 screws for the main contacts. Breaking capacity varies by voltage: 100 kA at 240 V, 100 kA at 400 V, 42 kA at 500 V, and 4 kA at 690 V — the 400 V figure is the one most often used for 400 V three-phase motor circuits in European panels. Phase failure detection is included, which is essential for preventing single-phasing damage on three-phase motors. Maximum switching frequency at AC-3 duty is 15 operations per hour, adequate for most pump, fan, and conveyor applications but not for high-cycling loads like stamping presses.","metaTitle":"Siemens 3RV2011-1JA10-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-1JA10-ZW97 SIRIUS motor protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 400 V, 45 mm wide. Current lifecycle stage. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 400 V":"gL/gG 50 A","at 500 V":"gL/gG 40 A","at 690 V":"gL/gG 40 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"1.5 hp","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"10 A","at 500 V rated value":"42 kA","at 600 V rated value":"10 A","at 690 V rated value":"4 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.5 hp","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"10 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"42 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"9.25 W","at AC-3 at 400 V rated value":"10 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"10 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"10 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (18 ... 14), 2x 12","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"3.1 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"130 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"7 ... 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e97120fbc2299be06cd96b1d1e1c8ab0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=271461&mlfb=3RV2011-1JA10-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1JA10-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What are the mounting dimensions for 3RV2011-1JA10-ZW97?","answer":"Width is 45 mm, depth is 97 mm, height is 97 mm. It snaps onto 35 mm DIN rail per DIN EN 60715."},{"question":"Does 3RV2011-1JA10-ZW97 include phase failure detection?","answer":"Yes, phase failure detection is included, protecting motors from single-phasing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1JA10-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1JA10-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}