{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1JA15-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1JA15-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1JA15-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1JA15-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2011-1JA15-ZW96 motor protection circuit breaker, Class 10, screw terminals, 45 mm wide, 97 mm deep, snap-on DIN rail mount.","salesMarkdown":"## Motor protection circuit breaker for Class 10 duty The Siemens 3RV2011-1JA15-ZW96 is a SIRIUS motor protection circuit breaker designed for Class 10 trip characteristics — meaning it will trip within 10 seconds at 7.2× the thermal setting, matching the startup profile of standard three-phase induction motors (pumps, fans, compressors) where the rotor is locked or stalled during start. The short-circuit ratings are given with specific upstream fuse types: 50 A gL/gG at 400 V, 40 A gL/gG at 500 V, and 40 A gL/gG at 690 V. Without those fuses, the breaker's own interrupting capacity at 690 V drops to 4 kA. For a 480 V line, the listed 10 A continuous rating and 100 kA at 400 V mean this breaker coordinates cleanly with a 100 A class J or gL fuse upstream — typical for a motor control center feeding a 5 hp motor at 460 V. The 1.5 hp at 230 V and 3 hp at 220/230 V ratings cover common single-phase and three-phase motor sizes in North American and European panels. Main circuit terminals are screw-type, accepting 2×(0.5…1.5 mm²) solid or stranded, or 2×(0.75…2.5 mm²). The M3 screw size is standard for panel wiring. Storage temperature range of -50 to +80 °C and operating range of -20 to +60 °C cover most indoor industrial environments. No ground-fault detection — that is handled separately by a residual-current device if needed.","metaTitle":"Siemens 3RV2011-1JA15-ZW96 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-1JA15-ZW96 SIRIUS motor protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 400 V, screw terminals, DIN rail mount. Current production. Quoted to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","at 24 V":"1 A","at 60 V":"0.15 A","at 120 V":"0.5 A","at 125 V":"0.5 A","at 230 V":"0.5 A","at 400 V":"gL/gG 50 A","at 500 V":"gL/gG 40 A","at 690 V":"gL/gG 40 A","Trip Class":"CLASS 10","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"1.5 hp","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"10 A","at 500 V rated value":"42 kA","at 600 V rated value":"10 A","at 690 V rated value":"4 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.5 hp","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"10 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"42 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"9.25 W","at AC-3 at 400 V rated value":"10 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"10 A","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"10 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","Of The Auxiliary And Control Contacts":"M3","at AC in hot operating state per pole":"3.1 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","contact rating of auxiliary contacts according to UL":"C300 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"130 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"7 ... 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f88fbf918b203c752ed60afb3d88c167.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1397192&mlfb=3RV2011-1JA15-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1JA15-ZW96/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for 3RV2011-1JA15-ZW96?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional alternative — 3RV2021-1GA15?","answer":"The 3RV2021-1GA15 is a physically larger (55 mm wide) SIRIUS breaker with a higher current range and different trip class. It will not drop into a panel cutout designed for the 45 mm 3RV2011-1JA15-ZW96 without a wider DIN-rail adapter or enclosure modification."},{"question":"What compliance documentation does Siemens provide for this breaker?","answer":"The SIRIUS series carries UL, CSA, CE, and IEC certifications standard for motor protection circuit breakers. RoHS and REACH declarations are available from Siemens documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1JA15-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1JA15-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}