{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1KA10-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1KA10-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1KA10-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1KA10-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-1KA10-ZW96, Trip Class 10, 100 kA breaking capacity at 400 V, screw-type terminals, 45 mm width, for 35 mm DIN rail.","salesMarkdown":"## Motor Protection Circuit Breaker, Trip Class 10 — SIRIUS 3RV2011-1KA10-ZW96 The Siemens 3RV2011-1KA10-ZW96 is a SIRIUS-brand motor protection circuit breaker with Trip Class 10. Rated operating voltage spans 20... 690 V, with a breaking capacity of 100 kA at 400 V and 42 kA at 500 V. Back-up fuse coordination is specified: gL/gG 63 A at 400 V, 50 A at 500 V, and 40 A at 690 V. These are the maximum upstream fuse ratings that preserve the breaker's interrupting capacity under short-circuit conditions. Ground fault detection is not included, so a separate ground-fault relay or RCD is needed if that function is required. Mounting position is any orientation. Clearance distances: 50 mm upwards and downwards, 30 mm at the sides, 0 mm forwards and backwards. These are the minimum air gaps to adjacent metalwork or other devices for proper arc quenching and heat dissipation. Main circuit terminals accept 2×(0.75... 2.5 mm²) solid or stranded, or 2×4 mm². Screw size is M3 for the main contacts. Dimensions: 97 mm depth, 45 mm width, 97 mm height. The compact footprint leaves room for additional devices in the same row. ## Operating Conditions and Switching Duty Maximum switching frequency is 15 operations per hour under AC-3 (motor starting) duty, and the same under AC-3e (enhanced motor protection) duty. This limits the breaker to applications with infrequent starts — not suitable for high-cycle jogging or reversing service. Motor horsepower ratings: 2 hp at 230 V, 3 hp at 200/208 V and 220/230 V, 8 hp at 460/480 V, and 0.5 hp at 110/120 V. These are the maximum motor sizes the breaker can protect at those voltages.","metaTitle":"Siemens 3RV2011-1KA10-ZW96 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-1KA10-ZW96 SIRIUS motor protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 400 V, screw terminals, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Trip Class":"CLASS 10","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d58de0405954b3902d659ac572599bfc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=333546&mlfb=3RV2011-1KA10-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1KA10-ZW96/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1KA10-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1KA10-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}