{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-1KA10-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-1KA10-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-1KA10-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1KA10-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2011-1KA10-ZX95 motor protection circuit breaker, Class 10 trip, 45 mm width, 100 kA interrupting at 400 V, screw terminals, active production.","salesMarkdown":"The Siemens 3RV2011-1KA10-ZX95 is a SIRIUS motor protection circuit breaker sized for a 12.5 A motor at 480 V, with a Class 10 trip curve that clears a stalled rotor fast enough to keep the winding insulation intact on standard induction motors. The 45 mm width (3-module DIN footprint) and 97 mm depth let it drop into a standard 3RV cutout. Clearance: 50 mm above and below for arc venting, 30 mm to the side, zero forward or backward. Any mounting position works. ## Interrupting & coordination The 3RV2011-1KA10-ZX95 carries a 100 kA interrupting rating at 240 V and 400 V, 42 kA at 500 V, and 4 kA at 690 V. The gL/gG fuse limits at the same voltages: 63 A at 400 V, 50 A at 500 V, 40 A at 690 V. If your panel has a 65 kA SCCR requirement, this breaker meets it at 400 V without extra hardware. The 3RV2023-4DA10 steps up to a higher current range (typically 22–32 A) and a higher interrupting capacity at 690 V. If your BOM calls for the 3RV2023-4DA10 but you only need 12.5 A, this unit drops in without rewiring — same terminal spacing, same screw-type connections. Just verify the trip class and current setting match your motor FLA. ## Integration & wiring Screw terminals on the main circuit accept 2x (0.75–2.5 mm²) solid or stranded, or 2x 4 mm². Main contact screws are M3. Torque to the Siemens spec (typically 1.2–1.5 Nm, verify on the nameplate). Operating temperature -20 to +60 °C; storage -50 to +80 °C. The wide voltage range (20–690 V) covers global line voltages without a different variant.","metaTitle":"Siemens 3RV2011-1KA10-ZX95 SIRIUS Motor Protection CB, Class","metaDescription":"Siemens 3RV2011-1KA10-ZX95 SIRIUS motor protection circuit breaker, Class 10 trip, 45 mm wide, 100 kA at 400 V, screw terminals, active production, RFQ for price and availability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Trip Class":"CLASS 10","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dee700f622e65201d6dce8920a7f6d22.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=311114&mlfb=3RV2011-1KA10-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-1KA10-ZX95/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-1KA10-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-1KA10-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}