{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-4AA10-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-4AA10-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-4AA10-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-4AA10-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-4AA10-ZW97, Class 10 trip, 100 kA breaking capacity at 240 V, 45 mm width, screw and snap-on DIN rail mount.","salesMarkdown":"No ground fault detection here — that's a separate add-on if your line needs it. The interrupting ratings tell you where this breaker can sit in the fault hierarchy: 100 kA at 240 V, 30 kA at 400 V, 5 kA at 500 V, 2 kA at 690 V. At 240 V it's a monster — you can put it upstream of a sub-panel and not worry about series rating gymnastics. At 690 V the 2 kA limit means it's fine for most motor branch circuits but check your available fault current if you're feeding from a large transformer. The fuse backup table (gL/gG 80 A at 240 V, 63 A at 400 V, 50 A at 500 V, 40 A at 690 V) gives the maximum upstream fuse that still allows the breaker to clear its rated fault — useful for selectivity coordination studies. Horsepower ratings: 1 hp at 110/120 V, 2 hp at 230 V, 3 hp at 200/208 V, 5 hp at 220/230 V. That covers the common small-motor sizes you'd find on pumps, fans, and small conveyors in a 480 V or 240 V delta panel. The AC-3 maximum switching rate is 15 operations per hour — fine for a start/run/stop cycle, not for jogging or frequent reversing. Width is 45 mm, depth 97 mm, height 97 mm — that's a standard 2-module-wide footprint on a 35 mm DIN rail per DIN EN 60715. Screw and snap-on mounting: clip it onto the rail, tighten the screw to lock it, no tools for the rail engagement. Mounting position is any, so you can lay it sideways in a shallow enclosure if the gland plate forces that. Terminals are screw-type for the main current circuit, accepting 2x 0.75...2.5 mm² solid or stranded, or 2x 4 mm². Main contact screws are M3. That's enough for the motor branch circuit wiring typical of a 5 hp motor at 230 V. Temperature compensation is active across the full operating range of -20 to +60 °C — the thermal trip curve stays accurate whether the panel is in a conditioned room or a hot pump house.","metaTitle":"Siemens 3RV2011-4AA10-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV2011-4AA10-ZW97 motor protection circuit breaker. Class 10, 100 kA at 240 V, 30 kA at 400 V. DIN rail mount. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Trip Class":"CLASS 10","Product Status":"Active","Temp Operating Max":"60 °C","Temp Operating Min":"-20 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/673a1413f046deac6adf7ea5c2b532ef.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=552693&mlfb=3RV2011-4AA10-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-4AA10-ZW97/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-4AA10-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-4AA10-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}