{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2021-4DA10-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2021-4DA10-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2021-4DA10-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2021-4DA10-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2021-4DA10-ZW97, Trip Class 10, 45 mm wide, screw-type terminals, phase failure detection, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"## Motor protection circuit breaker for Class 10 trip curve The Siemens 3RV2021-4DA10-ZW97 is a SIRIUS motor protection circuit breaker designed for motor protection, with a Trip Class 10 characteristic that clears a stalled-rotor overload within 10 seconds at 7.2× rated current — matching the thermal curve of standard IEC induction motors up to 15 hp at 460/480 V. It includes phase failure detection, which trips the breaker on loss of one phase to prevent single-phasing damage on delta-connected loads. ## Breaking capacity and back-up fuse coordination Rated short-circuit breaking capacity varies with line voltage: 100 kA at 240 V, 25 kA at 400 V, 5 kA at 500 V, and 2 kA at 690 V. For installations requiring higher fault-current withstand, the evidence specifies maximum back-up fuse ratings: gL/gG 63 A at 400 V, gL/gG 50 A at 500 V, and gL/gG 50 A at 690 V. These fuse values define the upstream coordination limit — select a fuse at or below these ratings to maintain the breaker's listed SCCR. ## Integration: panel footprint and wiring The breaker occupies a 45 mm wide DIN-rail footprint, with depth of 97 mm and height of 97 mm. Clearance requirements: 50 mm upwards, 50 mm downwards, 30 mm at the sides, zero forwards and zero backwards. Main circuit connections use screw-type terminals, accepting 2× (1 to 2.5 mm²) or 2× (2.5 to 10 mm²) solid or stranded copper; the main contact terminal screw size is M4.","metaTitle":"Siemens 3RV2021-4DA10-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2021-4DA10-ZW97 SIRIUS motor protection circuit breaker, Trip Class 10, 45 mm wide, screw terminals, phase failure detection. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Trip Class":"CLASS 10","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/69e3aae776a3a972c11948ccacc118a3.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=665283&mlfb=3RV2021-4DA10-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2021-4DA10-ZW97/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2021-4DA10-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2021-4DA10-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}