{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2021-4DA15-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2021-4DA15-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV2021-4DA15-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2021-4DA15-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2021-4DA15-ZX95, Class 10 trip, 25 kA breaking capacity at 400 V, phase failure detection, screw and snap-on 35 mm DIN rail mount.","salesMarkdown":"The Siemens SIRIUS 3RV2021-4DA15-ZX95 is a motor protection circuit breaker designed for Class 10 trip characteristics, meaning it will trip within 10 seconds at 7.2× the thermal setting — the standard for standard-duty induction motor starting where the rotor is not stalled during acceleration. It carries a 25 kA breaking capacity at 400 V, which is the figure that governs fault interruption in a 400 V distribution panel; the 100 kA rating at 240 V is relevant only for the North American split-phase context. Depth of 97 mm and height of 97 mm mean it projects about 97 mm forward from the rail; verify gland-plate depth if the enclosure is shallow. ## Breaking capacity and backup fusing The interrupting ratings span the common industrial voltages: 100 kA at 240 V, 25 kA at 400 V, 5 kA at 500 V, and 2 kA at 690 V. The 25 kA at 400 V is the one that matters for most European and Asian 400 V line-side faults; the 690 V rating drops to 2 kA, so if the supply transformer secondary is 690 V, verify the available fault current is below that. For backup protection by upstream fuses, the maximum fuse ratings are gL/gG 63 A at 400 V, 50 A at 500 V, and 50 A at 690 V — these are the fuse sizes that coordinate with the breaker's let-through energy. The auxiliary contact block (integrated or add-on, depending on variant) is rated 1 A at 24 V, 0.5 A at 120 V, 0.5 A at 125 V, 0.5 A at 230 V, and 0.15 A at 60 V. These are the maximum continuous currents the auxiliary contacts can switch; for a PLC input at 24 V, the 1 A rating is generous, but for a 230 V control relay coil, the 0.5 A limit means the coil inrush must stay under that. Terminal capacity for the main contacts is M4 screws, accepting 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²) solid or stranded.","metaTitle":"Siemens 3RV2021-4DA15-ZX95 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV2021-4DA15-ZX95 motor protection circuit breaker, Class 10 trip, 25 kA breaking capacity at 400 V. Phase failure detection, DIN rail mount. Sourced to order again","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Trip Class":"CLASS 10","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/69e3aae776a3a972c11948ccacc118a3.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=386867&mlfb=3RV2021-4DA15-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2021-4DA15-ZX95/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2021-4DA15-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2021-4DA15-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}