{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2031-4PB15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2031-4PB15","canonicalUrl":"https://aoctrl.com/siemens/3RV2031-4PB15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2031-4PB15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2031-4PB15, Trip Class 20, 30 kA breaking capacity at 400 V AC, phase failure detection, screw and snap-on DIN rail mounting.","salesMarkdown":"## Motor Protection Circuit Breaker for 400 V Panels It is rated for Trip Class 20, meaning it allows a 20-second overload duration at locked-rotor current before tripping — standard for general-purpose conveyors, pumps, and fans that don't need the fast trip of Class 10 or the extended ramp of Class 30. At 400 V, the 3RV2031-4PB15 delivers 30 kA breaking capacity, which is the common requirement for IEC motor control centers backed by a 400 V transformer. The interrupting rating at 500 V is 5 kA, and at 690 V it is 2 kA, which limits application on 690 V systems to low-fault-current scenarios. Dimensions are 55 mm wide, 140 mm high, and 149 mm deep — the 55 mm width is a single modular unit, so it occupies one 55 mm slot on the DIN rail. Main contact terminals accept M6 bolts, and the conductor cross-section ranges from 2x 0.5 mm² up to 2x 2.5 mm² solid or stranded. ## Switching Frequency and Auxiliary Ratings Maximum switching frequency under AC-3 and AC-3e duty is 15 operations per hour — adequate for motor start-stop cycles in material handling and conveyor applications, but not for high-speed jogging or reversing. Auxiliary contact ratings: 1 A at 24 V, 0.15 A at 60 V, 0.5 A at 230 V. At 110 V, 125 V, and 220 V the rated current is 0 A, meaning no auxiliary contact is available at those voltages — verify the control voltage before specifying.","metaTitle":"Siemens 3RV2031-4PB15 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens SIRIUS 3RV2031-4PB15 motor protection circuit breaker, Trip Class 20, 30 kA breaking capacity at 400 V AC, phase failure detection, current lifecycle. Sourced to order agai","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"149 mm","Width":"55 mm","Height":"140 mm","Trip Class":"CLASS 20","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4ac59e9ee2ba9ac36caaae3b52a6bf06.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=439421&mlfb=3RV2031-4PB15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2031-4PB15/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2031-4PB15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2031-4PB15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}