{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2032-4XA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2032-4XA10","canonicalUrl":"https://aoctrl.com/siemens/3RV2032-4XA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2032-4XA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, motor protection circuit breaker, 3RV2032-4XA10, 55 mm width, Trip Class 10, 50 kA at 400 V, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"It snaps onto a 35 mm DIN rail per DIN EN 60715 and accepts screw-type terminals for the main current circuit, handling conductors up to 2x 35 mm² or 1x 50 mm² solid or stranded. At 400 V the interrupting rating is 50 kA, which covers most industrial service-entrance and distribution panel fault levels. At 240 V it handles 100 kA, at 500 V it drops to 5 kA, and at 690 V it still manages 4 kA — enough for most motor branch circuits in a 480 V or 600 V plant. The continuous current rating at 480 V is 59 A, and the same at 600 V, so this breaker is sized for motor full-load currents in the 50–60 A range on a 480 V system. Width is 55 mm, height 140 mm, depth 149 mm. Mounting position is any orientation. Minimum clearance to adjacent metalwork: 50 mm above and below, 10 mm at the sides — no additional clearance needed at 240 V, but at 400 V you need 160 mm above, 125 mm at 500 V, and 100 mm at 690 V for arc-flash containment. Maximum switching frequency under AC-3 duty is 15 operations per hour, which suits motor starting cycles on pumps, fans, and conveyors — not high-speed jogging applications.","metaTitle":"Siemens 3RV2032-4XA10 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens SIRIUS 3RV2032-4XA10 motor protection circuit breaker, 55 mm wide, Trip Class 10, 50 kA at 400 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"149 mm","Width":"55 mm","title":"3RV2032-4XA10","Height":"140 mm","Upwards":"50 mm","at 240 V":"none required","at 400 V":"160","at 500 V":"125","at 690 V":"100","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S2 for motor protection, CLASS 10 A-release 49...59 A N-release 845 A screw terminal increased switching capacity","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M6","Mounting Position":"any","Solid Or Stranded":"2x (1 ... 35 mm²), 1x (1 ... 50 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"10 hp","at 240 V rated value":"100 kA","at 400 V rated value":"50 kA","at 480 V rated value":"59 A","at 500 V rated value":"5 kA","at 600 V rated value":"59 A","at 690 V rated value":"4 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"5 hp","at 220/230 V rated value":"20 hp","at 460/480 V rated value":"40 hp","at 575/600 V rated value":"50 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"10 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S2","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"20 000","at AC in hot operating state":"26 W","at AC-3 at 400 V rated value":"59 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"20 000","Substance Prohibitance (Date)":"03/01/2017","at AC-3e at 400 V rated value":"59 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"59 A","at AWG cables for main contacts":"2x (18 ... 2), 1x (18 ... 1)","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"8.7 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (1 ... 25 mm²), 1x (1 ... 35 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"3 ... 4.5 N·m","with high demand rate according to SN 31920":"50 %","shock resistance according to IEC 60068-2-27":"25g / 11 ms Sinus","Electrical Endurance (Operating Cycles) Typical":"20 000","Size Of Contactor Can Be Combined Company-Specific":"S2","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"845 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"49 ... 59 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4ac59e9ee2ba9ac36caaae3b52a6bf06.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=29269&mlfb=3RV2032-4XA10"},"ai":{"faq":[{"question":"Where can I buy 3RV2032-4XA10?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of 3RV2032-4XA10 at 400 V?","answer":"The interrupting rating at 400 V is 50 kA."},{"question":"What is the width of 3RV2032-4XA10?","answer":"The width is 55 mm."},{"question":"Does 3RV2032-4XA10 detect phase failure?","answer":"Yes, phase failure detection is built in."},{"question":"What Trip Class is 3RV2032-4XA10?","answer":"It is Trip Class 10, meaning it trips within 10 seconds at 7.2x the thermal setting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2032-4XA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2032-4XA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}