{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2041-4FA10-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2041-4FA10-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3RV2041-4FA10-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2041-4FA10-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2041-4FA10-0DA0, S3 circuit breaker for system protection, 40 A at AC-3, CLASS 10 trip, 65 kA SCCR at 400 V AC, screw terminals, DIN rail mount.","salesMarkdown":"The Siemens 3RV2041-4FA10-0DA0 is a SIRIUS S3 circuit breaker designed for system protection — meaning it sits upstream of a motor starter or feeder, not inside the starter itself. Rated 40 A at AC-3 (motor switching duty) up to 690 V maximum, this breaker handles the full-load current of a motor in that range and interrupts a fault up to 65 kA at 400 V AC — enough for most industrial panel SCCR requirements. The S3 frame size means it physically fits alongside the matching SIRIUS contactor and overload block in a coordinated starter assembly. The interrupting ratings span the voltage range you'll see in a plant: 100 kA at 240 V AC, 65 kA at 400 V AC, 12 kA at 500 V AC, and 5 kA at 690 V AC. The 30 kA rating at 400 V (listed separately) likely reflects the conditional SCCR when the breaker is paired with a specific upstream device; the 65 kA is the unconditional rating. ## Panel integration — mounting, terminals, and clearances The S3 frame is 70 mm wide, 165 mm tall, and 176 mm deep — that depth includes the screw terminals and any protruding cable. Main circuit terminals accept solid or stranded copper: 2x 2.5 to 16 mm² for the smaller conductor range, and 1x 10 to 70 mm² for the larger. The main contact screws are M8. That's a generous lug — sized for the 40 A rating with headroom for the full SCCR. ## Operating environment and duty cycle Mechanical endurance is typical 25,000 operations for the main contacts and auxiliary contacts.","metaTitle":"Siemens 3RV2041-4FA10-0DA0 SIRIUS Circuit Breaker, 40 A AC-3","metaDescription":"Siemens SIRIUS 3RV2041-4FA10-0DA0 circuit breaker, 40 A at AC-3, CLASS 10 trip, 65 kA SCCR at 400 V AC. S3 size, screw terminals, DIN rail mount. Current-production status. Sourced","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"176 mm","Width":"70 mm","Height":"165 mm","Trip Class":"CLASS 10","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7f7aca5ea19d99e6e6b7770a617768df.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1421695&mlfb=3RV2041-4FA10-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2041-4FA10-0DA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2041-4FA10-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2041-4FA10-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}