{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2041-4KA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2041-4KA15","canonicalUrl":"https://aoctrl.com/siemens/3RV2041-4KA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2041-4KA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2041-4KA15, Class 10 trip, 30 kA breaking capacity at 400 VAC, screw-type terminals, DIN rail mount.","salesMarkdown":"The breaker detects phase failure but does not include ground-fault detection — so if the application requires GF protection, that must be added externally via a residual-current device or ground-fault relay. At 240 VAC the breaker is rated for 100 kA, and at 690 VAC it drops to 3 kA. The 480 VAC rating is 75 A continuous, and the 600 VAC rating is also 75 A. The depth is 176 mm, width 70 mm, height 165 mm — verify these against your enclosure depth, especially if a door-mounted operator or auxiliary contact block is planned. Main circuit terminals are screw-type. Accepts solid or stranded copper: 2× (2.5 to 16 mm²) per clamp, or a single conductor up to 70 mm². The auxiliary contact terminals accept 2× (2.5 to 16 mm²) solid. Strip lengths and torque values per the datasheet — the screw terminals are robust for panel wiring but require a screwdriver, not a push-in tool. ## Switching frequency and thermal limits Maximum switching rate under AC-3 (motor) duty is 15 operations per hour, and the same limit applies under AC-3e. That is a deliberate thermal constraint on the bimetal element — exceeding it will cause nuisance tripping or accelerated aging of the overload mechanism. For applications requiring frequent starts (e.g., reversing or jogging), a contactor with a higher rated operational current and a separate overload relay would be a better fit. Per standard practice, derate the setting by 0.5% per °C above 40 °C ambient at the breaker location. If the buyer needs a cross-reference for a panel originally specified with a different SIRIUS frame size (e.g., 3RV2021 series), the mounting footprint and terminal layout differ — a direct drop-in without rewiring is not guaranteed. The 3RV2021-4NA25 and 3RV2021-4CA25 are smaller-frame siblings with lower breaking capacities and different terminal spacing; verify the panel cutout and busbar arrangement before substituting.","metaTitle":"Siemens 3RV2041-4KA15 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV2041-4KA15 SIRIUS motor protection circuit breaker, Class 10 trip, 30 kA breaking capacity at 400 VAC. Screw terminals, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"176 mm","Width":"70 mm","Height":"165 mm","Trip Class":"CLASS 10","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7f7aca5ea19d99e6e6b7770a617768df.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629965&mlfb=3RV2041-4KA15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2041-4KA15/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2041-4KA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2041-4KA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}