{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2041-4MA10-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2041-4MA10-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3RV2041-4MA10-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2041-4MA10-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, 3RV2041-4MA10-0DA0, S3 frame, 100 A AC-3, 65 kA SCCR at 400 V, Class 10, screw terminals, DIN-rail mount.","salesMarkdown":"The Siemens 3RV2041-4MA10-0DA0 is a SIRIUS circuit breaker for system protection — meaning it's sized to protect a feeder or a large motor branch, not just a single load. Trip class 10 means it opens fast enough to protect a standard induction motor during a locked-rotor event — that's the default for most pump, fan, and conveyor drives. S3 frame carries screw terminals that accept 2x 2.5–16 mm² solid or 1x 10–70 mm² stranded. That's a wide wire range for a 100 A breaker; you can land a single 70 mm² feed without adapters. Keep 150 mm clearance above and below, 30 mm to the sides for arc-chamber venting and heat dissipation. ## Ratings at a glance AC-3 motor rating: 100 A at 400 V, with a maximum switching frequency of 15 operations per hour. Rated operational voltage range is 20–690 V.","metaTitle":"Siemens 3RV2041-4MA10-0DA0 SIRIUS Circuit Breaker, 100 A AC-","metaDescription":"Siemens SIRIUS 3RV2041-4MA10-0DA0 circuit breaker, 100 A at AC-3, 65 kA SCCR at 400 V, Class 10 trip, S3 frame. Current lifecycle stage. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"176 mm","Solid":"2x (2.5 ... 16 mm²)","Width":"70 mm","title":"3RV2041-4MA10-0DA0","Height":"165 mm","Upwards":"150 mm","Downwards":"150 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S3 for system protection without phase failure protection A-release 80...100 A N-release 1300 A screw terminal Standard switching capacity","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M8","Mounting Position":"any","Solid Or Stranded":"2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"30 kW","at 400 V rated value":"30 kA","at 500 V rated value":"4 kA","at 690 V rated value":"3 kA","Design Of The Product":"for system protection","Ground Fault Detection":"No","Phase Failure Detection":"No","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"65 kA","at AC at 500 V rated value":"8 kA","at AC at 690 V rated value":"5 kA","Size Of The Circuit-Breaker":"S3","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"25 000","at AC in hot operating state":"44 W","at AC-3 at 400 V rated value":"100 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"25 000","Substance Prohibitance (Date)":"03/01/2017","at AC-3e at 400 V rated value":"100 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"100 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","For Main Contacts For Ring Cable Lug":"4.5 ... 6 N·m","Surge Voltage Resistance Rated Value":"8 kV","at AC in hot operating state per pole":"14.7 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","Finely Stranded Without Core End Processing":"2x (10 ... 35 mm²), 1x (10 ... 50 mm²)","For Main Contacts With Screw-Type Terminals":"4.5 ... 6 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms Sinus","Electrical Endurance (Operating Cycles) Typical":"25 000","Size Of Contactor Can Be Combined Company-Specific":"S3","Outer Diameter Of The Usable Ring Cable Lug Maximum":"19 mm","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"1 300 A","insulation voltage with degree of pollution 3 at AC rated value":"1 000 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"80 ... 100 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7f7aca5ea19d99e6e6b7770a617768df.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1421697&mlfb=3RV2041-4MA10-0DA0"},"ai":{"faq":[{"question":"Where can I buy 3RV2041-4MA10-0DA0 and get a price?","answer":"This part is sourced and quoted to order through independent distribution. Submit an RFQ — availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional second-source for 3RV2041-4MA10-0DA0?","answer":"The 3RV1011-1HA10 is a smaller-frame SIRIUS breaker (S0 vs S3) with lower current ratings — it won't drop into the same panel footprint or handle the same 100 A motor load without rewiring and re-coordination. No direct drop-in substitute exists."},{"question":"What is the depth of 3RV2041-4MA10-0DA0?","answer":"Depth is 176 mm, width 70 mm, height 165 mm."},{"question":"What wire sizes does 3RV2041-4MA10-0DA0 accept?","answer":"Screw terminals accept 2x 2.5–16 mm² solid or 1x 10–70 mm² stranded copper."},{"question":"Will 3RV2041-4MA10-0DA0 drop into a panel specified around 3RV1011-1HA10?","answer":"No — the S3 frame is physically larger (70 mm wide vs S0's 45 mm) and the terminal layout differs. You'd need to re-drill the mounting rail and re-terminate the conductors."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2041-4MA10-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2041-4MA10-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}