{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2042-4FB10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2042-4FB10","canonicalUrl":"https://aoctrl.com/siemens/3RV2042-4FB10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2042-4FB10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor-protective circuit breaker, 3RV2042-4FB10, CLASS 20, screw-type terminals, 100 kA breaking capacity at 400 V AC, 70 x 165 x 176 mm.","salesMarkdown":"## What this SIRIUS breaker does for a motor circuit The Siemens 3RV2042-4FB10 is a SIRIUS motor-protective circuit breaker designed to sit ahead of a contactor in a motor feeder. Its CLASS 20 trip curve means it allows a motor to draw starting current for up to 20 seconds at its locked-rotor current — enough for most pump, fan, and compressor starts without nuisance tripping, but tight enough to catch a stalled rotor before the motor windings cook. That's a high-fault-rated device — it can interrupt a bolted short-circuit on a 400 V bus without the upstream breaker needing to clear it. At 690 V AC it still holds 12 kA, enough for most 690 V motor circuits in mining or marine installations. ## Mounting and wiring — panel fit Any mounting position — horizontal, vertical, flat — so you can tuck it into tight enclosure corners. The 70 mm width and 165 mm height are standard SIRIUS frame sizes; the 176 mm depth leaves enough room for wiring behind a 200 mm deep enclosure. Accepts 2x (2.5... 16 mm²) solid or stranded on the line/load side, and up to 2x (2.5... 50 mm²) or 1x (10... 70 mm²) for larger conductors. That covers most motor feeder cables up to about 50 mm². The horsepower ratings tell you what motor it can protect: 7.5 hp at 230 V, 15 hp at 200/208 V and 220/230 V, 30 hp at 460/480 V, and 40 hp at 575/600 V. At 400 V, the breaking capacity is 50 kA — not the 100 kA you get at 400 V AC, so check which rating applies to your system voltage. The switching frequency is 15 operations per hour at AC-3 and AC-3e maximum — that's about one start every four minutes, which suits process motors but not rapid-cycling applications like stamping presses.","metaTitle":"Siemens 3RV2042-4FB10 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV2042-4FB10 SIRIUS motor-protective circuit breaker, CLASS 20, 100 kA breaking at 400 V AC. Screw terminals, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"176 mm","Width":"70 mm","Height":"165 mm","Trip Class":"CLASS 20","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7f7aca5ea19d99e6e6b7770a617768df.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629973&mlfb=3RV2042-4FB10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2042-4FB10/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2042-4FB10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2042-4FB10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}