{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2111-0HA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2111-0HA10","canonicalUrl":"https://aoctrl.com/siemens/3RV2111-0HA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2111-0HA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor-protective circuit breaker, 3RV2111-0HA10, 100 kA breaking capacity at 400 V AC, Class 10 trip, screw and snap-on mounting for 35 mm DIN rail.","salesMarkdown":"The Siemens 3RV2111-0HA10 is a SIRIUS motor-protective circuit breaker with integrated overload relay function — designed to protect motor feeders against short-circuit and overload in a single device. It carries a 100 kA breaking capacity at 400 V AC, also rated 100 kA at 500 V and 690 V. Ground fault detection is not included; if that's required, you'd need an upstream RCD or a separate ground-fault module. The rated switching frequency at AC-3 duty is 15 operations per hour — fine for a pump or fan cycling a few times an hour, not for a rapid-reversing application. Mounting position is any. The device footprint is 65 mm wide × 97 mm high × 97 mm deep — a standard two-module width on the DIN rail. Clearance requirements: 50 mm upwards and downwards, 30 mm at the sides; forwards and backwards clearance is 0 mm, so it can sit flush against the back panel. Main contact terminals are M3 screw-type, accepting 2× (0.5…1.5 mm²) or 2× (0.75…2.5 mm²) solid or stranded wire.","metaTitle":"Siemens 3RV2111-0HA10 SIRIUS Motor Circuit Breaker, 100 kA a","metaDescription":"Siemens 3RV2111-0HA10 SIRIUS motor-protective circuit breaker. 100 kA breaking capacity at 400 V AC, Class 10 trip, phase-failure detection. Current-production status. Available to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"65 mm","title":"3RV2111-0HA10","Height":"97 mm","Upwards":"50 mm","at 24 V":"1 A","Forwards":"0 mm","at 230 V":"1.5 A","at 690 V":"gL/gG 6 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for motor protection, CLASS 10 with overload relay function A-release 0.55...0.8 A N-release 10 A screw terminal Standard switching capacity","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.8 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.8 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection with overload relay function","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"0.8 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.8 A","Design Of The Auxiliary Switch":"laterally","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.8 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Of The Auxiliary And Control Contacts":"M3","at AC in hot operating state per pole":"2.4 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","contact rating of auxiliary contacts according to UL":"C600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 6 A, quick: 10 A","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.55 ... 0.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f61b49ea721a20b72380a4c7bccae278.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=144224&mlfb=3RV2111-0HA10"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RV2111-0HA10?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time."},{"question":"What is 3RV2111-0HA10's listed depth?","answer":"The depth is 97 mm. Overall dimensions are 65 mm wide × 97 mm high × 97 mm deep."},{"question":"Will 3RV2111-0HA10 drop into a panel specified around 3RV2011-0AA10 without rewiring?","answer":"Both are SIRIUS motor-protective circuit breakers with the same 65 mm width and snap-on DIN-rail mounting, so the footprint and rail position are compatible. Terminal type and wire range may differ — verify the 3RV2011-0AA10's terminal specs against the 3RV2111-0HA10's M3 screw terminals accepting 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²) before assuming a direct swap."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2111-0HA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2111-0HA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}