{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2331-4DC10-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2331-4DC10-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV2331-4DC10-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2331-4DC10-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker for starter combinations, 3RV2331-4DC10-ZX95, 55 mm wide, 149 mm deep, screw and snap-on mounting onto 35 mm DIN rail, 100 kA interrupting capacity at 240 V.","salesMarkdown":"## SIRIUS circuit breaker for starter combinations It mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, with a width of 55 mm and depth of 149 mm, fitting standard panel layouts without surprises. Rated for a voltage range of 20 to 690 V, its interrupting capacity hits 100 kA at 240 V, 30 kA at 400 V, and 3 kA at 690 V — figures that tell you this breaker handles high-fault-current scenarios at lower voltages while still clearing faults at 690 V. The 30 kA at 400 V is the number most panel builders will check first for industrial distribution. Required clearances: 50 mm upwards, 50 mm downwards, 10 mm at the side, and 0 mm forwards and backwards — so you can pack it tight against the backplane and adjacent devices, as long as you leave breathing room above and below for arc-quenching and thermal dissipation.","metaTitle":"Siemens 3RV2331-4DC10-ZX95 SIRIUS Circuit Breaker, 100 kA at","metaDescription":"Siemens SIRIUS 3RV2331-4DC10-ZX95 circuit breaker for starter combinations. 100 kA at 240 V, 30 kA at 400 V. DIN rail mount, 55 mm wide. Current production. Sourced to order agains","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"149 mm","Width":"55 mm","title":"3RV2331-4DC10-ZX95","Height":"140 mm","Upwards":"50 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"100","at 500 V":"80","at 690 V":"63","Backwards":"0 mm","Downwards":"50 mm","At The Side":"10 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S2 for starter combination Rated current 25 A N-release 325 A Screw terminal Standard switching capacity Reusable packaging = 24 units","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M6","Mounting Position":"any","Solid Or Stranded":"2x (1 ... 25 mm²), 1x (1 ... 35 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"5 hp","at 240 V rated value":"100 kA","at 400 V rated value":"30 kA","at 480 V rated value":"25 A","at 500 V rated value":"6 kA","at 600 V rated value":"25 A","at 690 V rated value":"3 kA","Design Of The Product":"For starter combinations","Ground Fault Detection":"No","Phase Failure Detection":"No","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"2 hp","at 200/208 V rated value":"7.5 hp","at 220/230 V rated value":"10 hp","at 460/480 V rated value":"20 hp","at 575/600 V rated value":"25 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"65 kA","at AC at 500 V rated value":"12 kA","at AC at 690 V rated value":"5 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S2","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"50 000","at AC in hot operating state":"14.5 W","at AC-3 at 400 V rated value":"25 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"50 000","Substance Prohibitance (Date)":"10/15/2014","at AC-3e at 400 V rated value":"25 A","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"25 A","at AWG cables for main contacts":"2x (18 ... 3), 1x (18 ... 2)","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"4.8 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (1 ... 16 mm²), 1x (1 ... 25 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"3 ... 4.5 N·m","with high demand rate according to SN 31920":"50 %","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms Sinus","Electrical Endurance (Operating Cycles) Typical":"50 000","Size Of Contactor Can Be Combined Company-Specific":"S2","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"325 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/044bda0585186c65b8d9454359912930.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=423836&mlfb=3RV2331-4DC10-ZX95"},"ai":{"faq":[{"question":"What are the key interrupting ratings for 3RV2331-4DC10-ZX95?","answer":"The interrupting capacity is 100 kA at 240 V, 30 kA at 400 V, 6 kA at 500 V, and 3 kA at 690 V."},{"question":"Where can I buy 3RV2331-4DC10-ZX95 and how is it quoted?","answer":"This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"Will 3RV2331-4DC10-ZX95 drop into a panel specified around 3RV2023-4DA10 without rewiring?","answer":"Both parts are SIRIUS circuit breakers for starter combinations with the same DIN-rail mounting footprint, but terminal sizes and ratings differ. The 3RV2331-4DC10-ZX95 uses M6 main contact terminals and accepts 2x (1–25 mm²) or 1x (1–35 mm²) conductors, so verify lug compatibility against the existing panel wiring before assuming a drop-in replacement."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2331-4DC10-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2331-4DC10-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}