{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2411-0EA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2411-0EA10","canonicalUrl":"https://aoctrl.com/siemens/3RV2411-0EA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2411-0EA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S00 circuit breaker, 3RV2411-0EA10, for transformer protection, Trip Class 10, 100 kA breaking capacity at 400 V AC, 45 mm wide, screw and snap-on DIN rail mount.","salesMarkdown":"That means its trip curve and ratings are tuned for the inrush and overload profile of a transformer primary, not a motor — the Trip Class 10 characteristic gives you a fast enough response to protect the winding without nuisance tripping on magnetizing inrush. The S00 frame size gives you a 45 mm wide body with 97 mm depth and height — about two standard MCB modules wide, so it fits neatly into a motor control center or distribution board. That zero forward clearance means it can sit flush against a panel door or busbar cover without extra standoffs. Screw-type terminals on the main circuit accept 2x 0.75–2.5 mm² or 2x 4 mm² solid/stranded; M3 screws on the main contacts. Use a Pozidriv size 2 tip with a 5–6 mm diameter shaft. Mounting position is any — handy for tight enclosures where you have to lay it on its side.","metaTitle":"Siemens 3RV2411-0EA10 SIRIUS Circuit Breaker, Transformer Pr","metaDescription":"Siemens 3RV2411-0EA10 SIRIUS S00 circuit breaker for transformer protection. 100 kA breaking capacity at 400 V AC. Trip Class 10. Phase failure detection. 45 mm wide. Available to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.4 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.4 A","at 690 V rated value":"100 kA","Design Of The Product":"For transformer protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.4 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.4 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.4 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"8.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.28 ... 0.4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d1e76f46e9e5863e7d4a060608e63675.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=447487&mlfb=3RV2411-0EA10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2411-0EA10/alternatives.json"},"ai":{"faq":[{"question":"Will 3RV2411-0EA10 drop into a panel designed for 3RV2011-0AA10?","answer":"Both are S00 frame size with the same 45 mm width and 35 mm DIN rail mount, so the physical footprint is the same. The terminal arrangement and screw-type connections are identical. The difference is the trip characteristic: the 3RV2411 is tuned for transformer protection, while the 3RV2011 series covers motor protection. Check your load type before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2411-0EA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2411-0EA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}