{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2411-0FA10-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2411-0FA10-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV2411-0FA10-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2411-0FA10-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, 3RV2411-0FA10-ZX95, for transformer protection, size S00, screw-type terminals, 100 kA breaking capacity at 400 V, Class 10 trip, DIN rail mount.","salesMarkdown":"Rated operating voltage spans 20 to 690 V, with a symmetrical breaking capacity of 100 kA at 240 V, 400 V, 500 V, and 690 V AC — meaning it clears faults up to that level without cascading upstream, a critical spec for transformer primary-side protection where available fault current can be high. Trip Class 10 ensures the breaker trips within 10 seconds at 7.2× rated current, matching the inrush profile of typical transformers (which can draw 8–12× rated for a few cycles) without nuisance tripping, while still protecting against sustained overloads. Ground fault detection is not included, so for systems requiring GF protection, an external device must be added. Storage and transport range extends to -50 to +80 °C. Screw-type terminals for the main current circuit accept solid or stranded conductors: 2× (0.75 to 2.5 mm²) or 2× 4 mm². Terminal screws use M3 thread, requiring a screwdriver shaft diameter of 5 to 6 mm — standard for panel wiring. Dimensions of 97 mm depth, 45 mm width, and 97 mm height, with required clearances of 50 mm upward and downward, 30 mm to the side, and zero forward/backward clearance — this fits tightly against the panel backplane, saving enclosure depth.","metaTitle":"Siemens 3RV2411-0FA10-ZX95 SIRIUS Circuit Breaker, Transform","metaDescription":"Siemens 3RV2411-0FA10-ZX95 SIRIUS circuit breaker for transformer protection. Class 10 trip, 100 kA breaking capacity at 400 V, screw terminals, DIN rail mount. Sourced to order ag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 690 V":"gL/gG 4 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.5 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.5 A","at 690 V rated value":"100 kA","Design Of The Product":"For transformer protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.5 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.5 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.35 ... 0.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e2190821bdc49beb8f5723a2b30410a7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=114492&mlfb=3RV2411-0FA10-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2411-0FA10-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Will 3RV2411-0FA10-ZX95 drop into a panel specified around 3RV2011-0AA10?","answer":"Both are SIRIUS size S00 breakers sharing the same DIN-rail footprint (45 mm width, 97 mm depth), so mechanical fit is identical. However, 3RV2411-0FA10-ZX95 is designed for transformer protection with a specific trip curve and phase failure detection — verify the trip characteristics match your application before substituting."},{"question":"What compliance documentation does Siemens provide for this breaker?","answer":"As a SIRIUS product, the 3RV2411-0FA10-ZX95 carries the standard Siemens declarations — RoHS, REACH, UL, and IEC certifications are typically included. Specific certificates should be requested at quote time for your jurisdiction."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2411-0FA10-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2411-0FA10-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}