{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2411-0HA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2411-0HA10","canonicalUrl":"https://aoctrl.com/siemens/3RV2411-0HA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2411-0HA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, 3RV2411-0HA10, Size S00, for transformer protection, 100 kA interrupting capacity at 400 V, Trip Class 10, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"The Siemens 3RV2411-0HA10 is a SIRIUS circuit breaker in the Size S00 frame, designed specifically for transformer protection. ## Panel fit and clearances At 97 mm deep, 45 mm wide, and 97 mm tall, the 3RV2411-0HA10 fits standard S00 panel cutouts. Screw-type terminals on the main circuit accept 2x 0.75–2.5 mm² solid/stranded or 2x 4 mm²; M3 screws for the main contacts, screwdriver shaft 5–6 mm diameter. ## Transformer protection and trip characteristics Rated operating voltage spans 20 to 690 V. Maximum switching frequency in AC-3 duty is 15 operations per hour. ## Interrupting ratings across voltages 100 kA interrupting capacity holds at 240 V, 400 V, 500 V, and 690 V AC — consistent fault clearance across common industrial supply voltages. At 230 V rated value, the motor power rating is 0.1 kW. At 480 V and 600 V, the rated current drops to 0.8 A. ## Environmental range and storage Any mounting position accepted.","metaTitle":"Siemens 3RV2411-0HA10 SIRIUS Circuit Breaker, Size S00, 100","metaDescription":"Siemens 3RV2411-0HA10 SIRIUS circuit breaker, Size S00, 100 kA interrupting at 400 V, Trip Class 10, transformer protection, DIN rail mount. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 690 V":"gL/gG 6 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.8 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.8 A","at 690 V rated value":"100 kA","Design Of The Product":"For transformer protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"0.8 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.8 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.8 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"16 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.55 ... 0.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$34.29","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3e967dff5aa9981046739c80c2455c50.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=325698&mlfb=3RV2411-0HA10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2411-0HA10/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3RV2411-0HA10 and how is it quoted for volume purchases?","answer":"Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing confirmed at quote time."},{"question":"When sourcing 3RV2411-0HA10, what's the closest functional second-source — 3RV2011-0AA10?","answer":"The 3RV2011-0AA10 is a smaller-frame SIRIUS breaker (Size S0 vs S00) with lower interrupting ratings. The 3RV2411-0HA10's 100 kA at 400 V and transformer-protection design are not matched by the 3RV2011-0AA10, so a direct drop-in replacement without rewiring is unlikely."},{"question":"What is 3RV2411-0HA10's listed depth (97 mm) on this component line?","answer":"The depth is 97 mm, width 45 mm, height 97 mm — standard S00 frame dimensions."},{"question":"Will 3RV2411-0HA10 drop into a panel that was specified around 3RV2011-0AA10 without rewiring?","answer":"No — the 3RV2411-0HA10 uses Size S00 frame (97×45×97 mm) while 3RV2011-0AA10 uses Size S0. Different footprint and terminal layout; rewiring and possibly re-punching the panel are required."},{"question":"What compliance documentation does this brand provide for 3RV2411-0HA10 (RoHS, REACH, UL, IEC)?","answer":"As a Siemens SIRIUS product, the 3RV2411-0HA10 carries CE marking and is designed to IEC/EN 60947 standards. UL and CSA listings are standard for the SIRIUS line. RoHS and REACH declarations are available from Siemens documentation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2411-0HA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2411-0HA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}