{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2411-1HA10-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2411-1HA10-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3RV2411-1HA10-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2411-1HA10-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker 3RV2411-1HA10-0BA0, Size S00, for transformer protection, 45 mm width, screw and snap-on mounting on 35 mm DIN rail, Class 10 trip.","salesMarkdown":"The Siemens 3RV2411-1HA10-0BA0 is a SIRIUS-brand circuit breaker specifically designed for transformer protection, not general motor or cable protection. Mount it any position you like; screw and snap-on both work. That's the key difference from a general-purpose motor-protective breaker (Class 10 is standard for motor starting too, but the curve here is tuned for transformer inrush). The interrupting ratings tell you what fault current it can safely clear: 100 kA at 400 V AC, 42 kA at 500 V AC, and 6 kA at 690 V AC. At 240 V AC it still holds 100 kA. The screw terminals accept 2× (0.75 to 2.5 mm²) solid or stranded, or 2× 4 mm². Use a Pozidriv size 2 tip with a 5 to 6 mm shaft diameter. Clearance distances: 50 mm upwards and downwards, 30 mm at the sides, zero forwards and backwards. That means you can butt it against the back panel and the door — no extra breathing space needed behind the rail.","metaTitle":"Siemens 3RV2411-1HA10-0BA0 SIRIUS Circuit Breaker, Transform","metaDescription":"Siemens 3RV2411-1HA10-0BA0 SIRIUS circuit breaker for transformer protection. 45 mm wide, screw/snap-on DIN rail mount. Class 10 trip. Sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 400 V":"gG 50 A","at 500 V":"gG 40 A","at 690 V":"gG 35 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-50 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"1.5 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 500 V rated value":"42 kA","at 690 V rated value":"4 kA","Design Of The Product":"For transformer protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"42 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"500","at AC in hot operating state":"9.25 W","at AC-3 at 400 V rated value":"8 A","Of Auxiliary Contacts Typical":"500","Substance Prohibitance (Date)":"03/01/2017","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"8 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"3.1 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"500","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"163 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"5.5 ... 8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/107c637edae82e16cd506d50bdb813b6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=377080&mlfb=3RV2411-1HA10-0BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2411-1HA10-0BA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV2411-1HA10-0BA0 and get current pricing?","answer":"We source this part to order. Availability and current pricing are confirmed at quote time against an RFQ — send us the order code and quantity for a firm quote."},{"question":"What is the difference between 3RV2411-1HA10-0BA0 and 3RV2011-0AA10?","answer":"The 3RV2411-1HA10-0BA0 is a dedicated transformer-protection breaker, while the 3RV2011-0AA10 is a general motor-protective breaker. Both are Size S00 and mount on 35 mm DIN rail, but the trip curve and thermal settings differ — the 3RV2411 handles transformer inrush without nuisance tripping, whereas the 3RV2011 is tuned for motor starting. They are not drop-in substitutes without verifying the load profile."},{"question":"What are the interrupting ratings for 3RV2411-1HA10-0BA0?","answer":"100 kA at 240 V AC and 400 V AC, 42 kA at 500 V AC, and 6 kA at 690 V AC. These are high enough to handle most industrial distribution panels without upstream fusing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2411-1HA10-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2411-1HA10-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}