{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2411-1KA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2411-1KA10","canonicalUrl":"https://aoctrl.com/siemens/3RV2411-1KA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2411-1KA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2411-1KA10 circuit breaker for transformer protection, Class 10 trip, 100 kA interrupting capacity at 400 V, 45 mm wide, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"## Transformer-rated motor branch protection in a 45 mm footprint At 45 mm wide and 97 mm deep, this breaker occupies a single 45 mm slot on a 35 mm DIN rail per DIN EN 60715. The screw-and-snap-on fastening lets a panel builder pre-wire the terminals and snap the unit in last — no loose hardware inside the enclosure. Ground fault detection is not included — that stays external if the application requires it. ## SCCR headroom and fuse backup coordination At 690 V the interrupting rating drops to 4 kA, so a 690 V installation needs upstream fuse coordination; the evidence specifies gL/gG backup fuses: 63 A at 400 V, 50 A at 500 V, 40 A at 690 V. For motor branch circuits, the horsepower ratings per voltage tell you the maximum motor this breaker can back up: 2 hp at 230 V, 3 hp at 200–230 V, 8 hp at 460–480 V. These are the values a panel builder uses for UL 508A sizing — the breaker's own thermal setting must be adjusted to the motor FLA, not the transformer primary. Main circuit terminals are screw-type, accepting 2x 0.75–2.5 mm² solid/stranded or 2x 4 mm². The M3 screw size is standard for panel wiring; torque to the manufacturer's spec for the terminal material. Clearance distances: 50 mm upwards and downwards, 30 mm at the sides — no extra space needed forwards or backwards, which helps when the breaker sits against a gland plate or backplane. The Class 10 trip curve limits switching frequency to 15 operations per hour at AC-3 and AC-3e duty — adequate for transformer inrush cycles but not for frequent motor starting.","metaTitle":"Siemens 3RV2411-1KA10 SIRIUS Circuit Breaker, Class 10, 100","metaDescription":"Siemens 3RV2411-1KA10 SIRIUS circuit breaker for transformer protection. Class 10 trip, 100 kA SCCR at 400 V, 45 mm wide, DIN-rail mount. Current lifecycle stage; sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Trip Class":"CLASS 10","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$40.64","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d2d44171a860f2d6d435e7e9a255b078.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=94801&mlfb=3RV2411-1KA10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2411-1KA10/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2411-1KA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2411-1KA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}