{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2711-0AD10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2711-0AD10","canonicalUrl":"https://aoctrl.com/siemens/3RV2711-0AD10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2711-0AD10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, 3RV2711-0AD10, size S00, 100 kA breaking capacity at 400 V AC, screw and snap-on mounting on 35 mm DIN rail, for system protection per UL 489/CSA C22.2 No. 5.","salesMarkdown":"The Siemens 3RV2711-0AD10 is a SIRIUS circuit breaker in the S00 frame, designed for system protection per UL 489 and CSA C22.2 No. 5. Rated breaking capacity hits 100 kA at 240 V, 400 V, 500 V, and 690 V AC — that is the same 100 kA figure across the board, so it handles high-fault utility feeds without needing an upstream current-limiting fuse for most installations. No official successor has been assigned, and no PCN has been issued. The part is still the standard catalog offering in the SIRIUS range for this frame size and breaking capacity. ## Panel integration — dimensions and wiring Dimensions are 97 mm deep, 45 mm wide, 144 mm tall. Clearance requirements: 70 mm upward and downward, 30 mm at the sides, zero forward or backward — that matters when you are packing multiple breakers into a gland-plate-limited panel. Screw-type terminals with M4 screws; use a Pozidriv size 2 tip or a 5-6 mm diameter screwdriver shaft. Strip length and torque are standard for this class — no special tooling needed. Rated operational voltage spans 20 to 690 V, covering most low-voltage industrial systems. At 230 V the motor power rating is 0 kW — this breaker is not sized for motor starting at that voltage; its strength is system protection at higher fault currents. Mechanical endurance is 100,000 operating cycles typical for the main contacts. The maximum switching rate under AC-3 or AC-3e duty is 15 operations per hour — adequate for infrequent motor starts, not for rapid cycling applications like indexing conveyors. Power dissipation at AC in hot operating state is 5.5 W — negligible for thermal panel calculations but worth noting if you are packing many units in a sealed enclosure. No ground fault or phase failure detection built in — this is a straight thermal-magnetic or electronic overcurrent protector, not a multifunction motor protection relay. For phase-loss-sensitive loads, you would add an external phase monitoring relay upstream.","metaTitle":"Siemens 3RV2711-0AD10 SIRIUS Circuit Breaker, 100 kA at 400","metaDescription":"Siemens 3RV2711-0AD10 SIRIUS circuit breaker, size S00, 100 kA breaking capacity at 400 V AC. UL 489/CSA design. Screw/snap-on 35 mm DIN rail. Current lifecycle. Available to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","title":"3RV2711-0AD10","Height":"144 mm","Upwards":"70 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"70 mm","At The Side":"30 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for system protection with approval circuit breaker UL 489, CSA C22.2 No.5-02 A-release 0.16 A N-release 2.1 A screw terminal Standard switching capacity","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M4","Mounting Position":"any","Solid Or Stranded":"1 ... 10 mm², max. 2x 10 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 500 V rated value":"100 kA","at 690 V rated value":"100 kA","Design Of The Product":"For system protection according to UL 489/CSA C22.2 No. 5","Ground Fault Detection":"No","Phase Failure Detection":"No","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.16 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.16 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.16 A","at AWG cables for main contacts":"2x (14 ... 10)","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"1 ... 16 mm², max. 6 + 16 mm²","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"2.5 ... 3 N·m","with high demand rate according to SN 31920":"50 %","shock resistance according to IEC 60068-2-27":"25 g / 11 ms (rectangular impulse and sine pulse)","Electrical Endurance (Operating Cycles) Typical":"100 000","at 480 AC Y/277 V according to UL 489 rated value":"65 kA","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"2.1 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$64.77","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b34b3ad9b357990a64ba38ca725154d2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=376196&mlfb=3RV2711-0AD10"},"ai":{"faq":[{"question":"Where can I buy 3RV2711-0AD10 and what is the lead time?","answer":"This part is sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time against an RFQ — no stock count or lead-time figure is published here, but the supply channel is open and active."},{"question":"Will 3RV2711-0AD10 drop into a panel specified around 3RV2011-0AA10?","answer":"Both are SIRIUS circuit breakers in the S00 frame with the same DIN-rail mounting footprint (35 mm per DIN EN 60715). The 3RV2711-0AD10 carries a 100 kA breaking capacity across the voltage range, while the 3RV2011-0AA10 is a different variant — verify the interrupting rating and trip characteristics for your specific fault current before substituting. Mechanically it fits the same rail slot."},{"question":"What compliance documentation does Siemens provide for 3RV2711-0AD10?","answer":"The breaker is designed for system protection per UL 489 and CSA C22.2 No. 5. Standard Siemens documentation includes the declaration of conformity (CE), RoHS and REACH compliance statements, and the UL/CSA file number available through the Siemens Industry Online Support portal."},{"question":"What is the depth of 3RV2711-0AD10?","answer":"97 mm depth, with 45 mm width and 144 mm height. Clearance: 70 mm above and below, 30 mm at the sides, zero forward or backward."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2711-0AD10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2711-0AD10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}