{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2711-0ED10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2711-0ED10","canonicalUrl":"https://aoctrl.com/siemens/3RV2711-0ED10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2711-0ED10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, 3RV2711-0ED10, size S00, 100 kA breaking capacity at 400 V AC, UL 489/CSA C22.2 No. 5, screw and snap-on 35 mm DIN rail mount.","salesMarkdown":"## What the 100 kA rating means for your panel The Siemens 3RV2711-0ED10 is a SIRIUS-brand circuit breaker in the size S00 frame, designed for system protection per UL 489 and CSA C22.2 No. 5. That level of SCCR (short-circuit current rating) is typical for industrial main feeders or large motor branch circuits where the available fault current from the transformer is high. The breaker mounts via screw fixing or snap-on onto a 35 mm DIN rail per DIN EN 60715, and accepts conductor sizes from 1 to 10 mm² (up to 2x 10 mm²) at the screw-type terminals. ## Integration into a DIN-rail panel Clearance requirements: 70 mm upward, 70 mm downward, 30 mm at the side, and zero forward/backward clearance needed. Mounting position is any orientation. The screwdriver shaft diameter for the main contact terminals is 5 to 6 mm, with a Pozidriv size 2 tip. This part carries a current lifecycle stage — no end-of-life notification or phase-out has been issued. It remains an active catalog item in the SIRUS range. No official successor has been published, so the BOM line stays stable. The rated insulation voltage spans 20 to 690 V. Power dissipation in hot operating state at AC is 5.5 W. Ground fault and phase failure detection are not built in — those functions require an external relay or a different variant.","metaTitle":"Siemens 3RV2711-0ED10 SIRIUS Circuit Breaker, 100 kA at 400","metaDescription":"Siemens 3RV2711-0ED10 SIRIUS circuit breaker, size S00, 100 kA breaking capacity at 400 V AC. UL 489/CSA C22.2 No. 5. Screw/snap-on 35 mm DIN rail. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"144 mm","Upwards":"70 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"70 mm","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M4","Mounting Position":"any","Solid Or Stranded":"1 ... 10 mm², max. 2x 10 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 500 V rated value":"100 kA","at 690 V rated value":"100 kA","Design Of The Product":"For system protection according to UL 489/CSA C22.2 No. 5","Ground Fault Detection":"No","Phase Failure Detection":"No","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.4 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.4 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.4 A","at AWG cables for main contacts":"2x (14 ... 10)","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"1 ... 16 mm², max. 6 + 16 mm²","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"2.5 ... 3 N·m","with high demand rate according to SN 31920":"50 %","shock resistance according to IEC 60068-2-27":"25 g / 11 ms (rectangular impulse and sine pulse)","Electrical Endurance (Operating Cycles) Typical":"100 000","at 480 AC Y/277 V according to UL 489 rated value":"65 kA","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"5.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$64.77","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=165828&mlfb=3RV2711-0ED10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2711-0ED10/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RV2711-0ED10 at 400 V?","answer":"100 kA at 400 V AC, and the same 100 kA rating holds at 240 V, 500 V, and 690 V AC."},{"question":"Will 3RV2711-0ED10 drop into a panel specified around 3RV2011-0AA10?","answer":"Both are size S00 circuit breakers on a 35 mm DIN rail, so the footprint and mounting are identical. The 3RV2711-0ED10 carries a 100 kA breaking capacity versus the 3RV2011-0AA10's lower rating, so it is a direct mechanical replacement if the higher SCCR is acceptable for the circuit. Verify the trip curve and current rating against the original BOM before swapping."},{"question":"Where can I buy 3RV2711-0ED10?","answer":"This part is sourced and quoted to order against an RFQ through independent industrial distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2711-0ED10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2711-0ED10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}