{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2711-1BD10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2711-1BD10","canonicalUrl":"https://aoctrl.com/siemens/3RV2711-1BD10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2711-1BD10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, 3RV2711-1BD10, size S00, 45 mm wide, 100 kA breaking capacity at 400 V AC, screw and snap-on 35 mm DIN rail mount, for system protection per UL 489.","salesMarkdown":"The Siemens 3RV2711-1BD10 is a SIRIUS circuit breaker, size S00, designed for system protection according to UL 489 and CSA C22.2 No. 5. That means it's built to serve as a branch-circuit protective device in North American panels — not just a motor-protective overload relay, but a listed breaker that clears faults upstream of the load. At 400 V AC this breaker is rated 100 kA interrupting capacity. That's the same at 240 V AC and 500 V AC — 100 kA each — so it handles high-available-fault panels without cascading upstream. The breaker also lists backup fuse requirements: gG 25 A at 400 V and 500 V, gG 20 A at 690 V. If you're coordinating with upstream fuses, those are the maximum ratings for the backup protection to hold the breaker's SCCR. The screwdriver shaft diameter is 5 to 6 mm, Pozidriv size 2. Main contact terminals use M4 screws.","metaTitle":"Siemens 3RV2711-1BD10 SIRIUS Circuit Breaker, 100 kA at 400","metaDescription":"Siemens 3RV2711-1BD10 SIRIUS circuit breaker, size S00, 45 mm wide, 100 kA breaking capacity at 400 V AC. Designed for system protection per UL 489. Active production. Quoted to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","title":"3RV2711-1BD10","Height":"144 mm","Upwards":"70 mm","Forwards":"0 mm","at 400 V":"gG 25 A","at 500 V":"gG 25 A","at 690 V":"gG 20 A","Backwards":"0 mm","Downwards":"70 mm","At The Side":"30 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for system protection with approval circuit breaker UL 489, CSA C22.2 No.5-02 A-release 2 A N-release 26 A screw terminal Standard switching capacity","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M4","Mounting Position":"any","Solid Or Stranded":"1 ... 10 mm², max. 2x 10 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.4 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 500 V rated value":"100 kA","at 690 V rated value":"10 kA","Design Of The Product":"For system protection according to UL 489/CSA C22.2 No. 5","Ground Fault Detection":"No","Phase Failure Detection":"No","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"10 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"2 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"2 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"2 A","at AWG cables for main contacts":"2x (14 ... 10)","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"1 ... 16 mm², max. 6 + 16 mm²","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"2.5 ... 3 N·m","with high demand rate according to SN 31920":"50 %","Electrical Endurance (Operating Cycles) Typical":"100 000","at 480 AC Y/277 V according to UL 489 rated value":"65 kA","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"26 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$69.85","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8b3967505cc2f217488f9e6492c9735b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=278994&mlfb=3RV2711-1BD10"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RV2711-1BD10?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"What is 3RV2711-1BD10's listed depth and width?","answer":"Depth is 97 mm, width is 45 mm, height is 144 mm. The 45 mm width is the same as the S00 frame size standard."},{"question":"What compliance documentation does this brand provide for 3RV2711-1BD10?","answer":"The breaker is designed for system protection according to UL 489 and CSA C22.2 No. 5. Standard SIRIUS documentation includes RoHS and REACH declarations; specific certificates are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2711-1BD10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2711-1BD10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}