{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2711-1ED10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2711-1ED10","canonicalUrl":"https://aoctrl.com/siemens/3RV2711-1ED10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2711-1ED10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, circuit breaker, Size S00, 3RV2711-1ED10, 100 kA breaking capacity at 400 V AC, screw-type terminals, DIN rail mount.","salesMarkdown":"## What this breaker does on the line The Siemens 3RV2711-1ED10 is a SIRIUS Size S00 circuit breaker built for system protection per UL 489 and CSA C22.2 No. 5. The 100 kA holds at 240 V and 500 V too; at 690 V it drops to 4 kA (6 kA AC). For backup protection, the manufacturer specifies gG fuses: 32 A at 400/500 V, 25 A at 690 V. Rated voltage spans 20 to 690 V, covering most industrial control voltages. The motor-switching rating at AC-3 is 0.8 kW at 230 V, with a maximum of 15 operations per hour. No ground-fault or phase-failure detection built in — this is a straight thermal-magnetic or electronic overcurrent trip, not a multifunction motor manager. ## Panel fit and clearances The S00 frame takes a 45 mm wide footprint on the rail, 97 mm deep, 144 mm tall. Any mounting position works. Terminals accept 1 to 10 mm² solid or stranded (up to 2x 10 mm²), with M4 screws on the main contacts; use a Pozidriv size 2 tip or a 5–6 mm diameter screwdriver shaft.","metaTitle":"Siemens 3RV2711-1ED10 SIRIUS Circuit Breaker, 100 kA at 400","metaDescription":"Siemens 3RV2711-1ED10 SIRIUS Size S00 circuit breaker. 100 kA breaking capacity at 400 V AC, UL 489 listed. DIN rail mount, screw terminals. Sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","title":"3RV2711-1ED10","Height":"144 mm","Upwards":"70 mm","Forwards":"0 mm","at 400 V":"gG 32 A","at 500 V":"gG 32 A","at 690 V":"gG 25 A","Backwards":"0 mm","Downwards":"70 mm","At The Side":"30 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for system protection with approval circuit breaker UL 489, CSA C22.2 No.5-02 A-release 4 A N release 52 A screw terminal Standard switching capacity","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M4","Mounting Position":"any","Solid Or Stranded":"1 ... 10 mm², max. 2x 10 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.8 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 500 V rated value":"100 kA","at 690 V rated value":"4 kA","Design Of The Product":"For system protection according to UL 489/CSA C22.2 No. 5","Ground Fault Detection":"No","Phase Failure Detection":"No","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"4 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"4 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"4 A","at AWG cables for main contacts":"2x (14 ... 10)","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"1 ... 16 mm², max. 6 + 16 mm²","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"2.5 ... 3 N·m","with high demand rate according to SN 31920":"50 %","shock resistance according to IEC 60068-2-27":"25 g / 11 ms (rectangular impulse and sine pulse)","Electrical Endurance (Operating Cycles) Typical":"100 000","at 480 AC Y/277 V according to UL 489 rated value":"65 kA","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"52 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$69.85","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0f72dfdd00f6fbc11476921c8e2c24f8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=236431&mlfb=3RV2711-1ED10"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RV2711-1ED10 at 400 V?","answer":"100 kA at 400 V AC. The same rating applies at 240 V and 500 V. At 690 V it drops to 4 kA (6 kA AC)."},{"question":"What compliance standards does 3RV2711-1ED10 meet?","answer":"Designed for system protection per UL 489 and CSA C22.2 No. 5. It also carries the SIRIUS brand designation and mounts on standard 35 mm DIN rail per DIN EN 60715."},{"question":"Where can I buy 3RV2711-1ED10 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here."},{"question":"Will 3RV2711-1ED10 drop into a panel built for 3RV2021-1FA15?","answer":"Both are S00 frame breakers on 35 mm DIN rail, so the footprint and rail clip are identical. But the 3RV2711-1ED10 is a UL 489 system-protection device, while the 3RV2021-1FA15 may have different trip curves or interrupting ratings — verify the panel's SCCR and coordination study before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2711-1ED10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2711-1ED10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}