{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2711-1GD10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2711-1GD10","canonicalUrl":"https://aoctrl.com/siemens/3RV2711-1GD10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2711-1GD10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, size S00, 3RV2711-1GD10, screw and snap-on DIN rail mount, 100 kA SCCR at 400/500 V AC, UL 489/CSA C22.2 No.5 design.","salesMarkdown":"## SIRIUS circuit breaker, size S00 — 100 kA SCCR for system protection The Siemens 3RV2711-1GD10 is a SIRIUS-brand circuit breaker in the compact S00 frame, designed for system protection per UL 489 and CSA C22.2 No. 5. It delivers 100 kA short-circuit current rating (SCCR) at 400 V AC and 500 V AC, dropping to 4 kA at 690 V AC — numbers that tell you it can sit upstream of a panel without needing a current-limiting fuse for most industrial service. The breaker mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715, and the S00 size (97 mm deep, 45 mm wide, 144 mm tall) fits standard panel layouts with 70 mm clearance above and below, 30 mm to the sides. ## Backup fuse coordination — gG ratings by voltage When upstream protection is needed, the breaker coordinates with gG fuses at specific voltages: 50 A at 400 V, 40 A at 500 V, and 35 A at 690 V. That means if you're feeding this breaker from a 400 V supply, a 50 A gG fuse upstream will clear faults without nuisance trips or damage to the breaker. The rated operational voltage span is 20 to 690 V, covering most low-voltage industrial networks. ## Mounting and wiring — DIN rail, screw terminals, any position The screwdriver shaft needs a 5 to 6 mm diameter, Pozidriv size 2 tip. Main contact screws are M4.","metaTitle":"Siemens 3RV2711-1GD10 SIRIUS Circuit Breaker, 100 kA SCCR, S","metaDescription":"Siemens 3RV2711-1GD10 SIRIUS circuit breaker, size S00. 100 kA SCCR at 400/500 V AC. Screw and snap-on DIN rail mount. UL 489/CSA C22.2 No.5. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","title":"3RV2711-1GD10","Height":"144 mm","Upwards":"70 mm","Forwards":"0 mm","at 400 V":"gG 50 A","at 500 V":"gG 40 A","at 690 V":"gG 35 A","Backwards":"0 mm","Downwards":"70 mm","At The Side":"30 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for system protection with approval circuit breaker UL 489, CSA C22.2 No.5-02 A-release 6.3 A N-release 82 A screw terminal Standard switching capacity","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M4","Mounting Position":"any","Solid Or Stranded":"1 ... 10 mm², max. 2x 10 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"1.5 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 500 V rated value":"100 kA","at 690 V rated value":"4 kA","Design Of The Product":"For system protection according to UL 489/CSA C22.2 No. 5","Ground Fault Detection":"No","Phase Failure Detection":"No","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"6 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"6.3 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"6.3 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"6.3 A","at AWG cables for main contacts":"2x (14 ... 10)","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"1 ... 16 mm², max. 6 + 16 mm²","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"2.5 ... 3 N·m","with high demand rate according to SN 31920":"50 %","shock resistance according to IEC 60068-2-27":"25 g / 11 ms (rectangular impulse and sine pulse)","Electrical Endurance (Operating Cycles) Typical":"100 000","at 480 AC Y/277 V according to UL 489 rated value":"65 kA","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"82 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$69.85","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/713270e12e18603b93487dbdfb38723e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=472885&mlfb=3RV2711-1GD10"},"ai":{"faq":[{"question":"Where can I buy 3RV2711-1GD10 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time."},{"question":"What is 3RV2711-1GD10's depth and width?","answer":"Depth is 97 mm, width is 45 mm, height is 144 mm — the standard S00 frame footprint."},{"question":"What compliance documentation does this brand provide for 3RV2711-1GD10?","answer":"The breaker is designed for system protection per UL 489 and CSA C22.2 No. 5. It carries the SIRIUS brand from Siemens. Specific RoHS/REACH declarations are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2711-1GD10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2711-1GD10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}