{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2742-5AD10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2742-5AD10","canonicalUrl":"https://aoctrl.com/siemens/3RV2742-5AD10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2742-5AD10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, 3RV2742-5AD10, S3 frame, 10 A rated operational current, 100 kA breaking capacity at 240 V AC, screw-type terminals, for system protection per UL 489/CSA C22.2 No. 5.","salesMarkdown":"The Siemens 3RV2742-5AD10 is a SIRIUS circuit breaker in the S3 frame, designed for system protection per UL 489 and CSA C22.2 No. 5. It carries a rated operational current of 10 A and operates at 50/60 Hz with a rated voltage range of 20 to 600 V. The overload release is thermal; the short-circuit trip is magnetic. Breaking capacity reaches 100 kA at 240 V AC and 50 kA at 400 V AC (with an alternative rating of 100 kA at 400 V AC also listed). The S3 frame size and M8 main-contact terminals handle solid or stranded conductors up to 70 mm² (single) or 50 mm² (double). Screw-type terminals with a hexagonal socket (4 mm tip) are standard. The 100 kA breaking capacity at 240 V AC and 50 kA at 400 V AC (with a second entry showing 100 kA at 400 V AC) means this breaker can safely interrupt fault currents up to those levels without upstream devices needing to clear first. The thermal overload release (rated 10 A) protects against sustained overcurrents; the magnetic short-circuit trip handles instantaneous faults. The 25 000 typical mechanical/electrical cycles for main and auxiliary contacts give a baseline for maintenance scheduling in high-cycle applications like conveyor or pump control. ## Mounting and integration — DIN-rail fit and clearances Dimensions: 70 mm wide, 170 mm high, 176 mm deep. Required clearances: 70 mm above, 70 mm below, 10 mm to the side. These clearances are for heat dissipation and arc venting — respect them in a crowded enclosure. Terminals accept solid or stranded copper: 2x (2.5 to 16 mm²) for the control circuit, and up to 1x (10 to 70 mm²) or 2x (2.5 to 50 mm²) for the main circuit. AWG 14 solid fits the front clamping point only. The hexagonal socket screwdriver tip is 4 mm. Relative humidity during operation: 10 to 95 %. The substance prohibition date (RoHS/REACH compliance) is March 1, 2017. No ground-fault or phase-failure detection built in — those functions require an external module or a different breaker variant.","metaTitle":"Siemens 3RV2742-5AD10 SIRIUS Circuit Breaker, 10 A, 100 kA a","metaDescription":"Siemens 3RV2742-5AD10 SIRIUS circuit breaker, 10 A rated current, 100 kA breaking capacity at 240 V AC. UL 489/CSA system protection. S3 frame, screw terminals. Current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"176 mm","Width":"70 mm","Height":"170 mm","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e2ddffe8cd0b47c311091c38dc3516d1.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=630007&mlfb=3RV2742-5AD10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2742-5AD10/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2742-5AD10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2742-5AD10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}