{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2811-0BD10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2811-0BD10","canonicalUrl":"https://aoctrl.com/siemens/3RV2811-0BD10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2811-0BD10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2811-0BD10 circuit breaker, S00 size, 100 kA breaking capacity at 400 V AC, for transformer protection per UL 489, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"## Integrator note — SIRIUS 3RV2811-0BD10 The Siemens 3RV2811-0BD10 is a SIRIUS circuit breaker sized S00, designed specifically for transformer protection and listed under UL 489 / CSA C22.2 No.5. The 45 mm width and 97 mm depth fit a standard 45 mm-wide module slot; plan for 70 mm clearance above and below, 30 mm at the sides, zero forward or backward clearance needed. Rated voltage span covers 20 to 690 V. ## Panel integration — clearance and wiring Use a Pozidriv size 2 screwdriver with a 5 to 6 mm shaft diameter. Main contact screws are M4. Ground fault and phase failure detection are not built-in — the breaker is a straight thermal-magnetic device for transformer protection. Clearance: 70 mm above and below the breaker, 30 mm at the sides, zero forward or backward. This keeps arc-flash venting and thermal dissipation within manufacturer limits.","metaTitle":"Siemens 3RV2811-0BD10 SIRIUS Circuit Breaker, 100 kA at 400","metaDescription":"Siemens 3RV2811-0BD10 SIRIUS circuit breaker, 100 kA breaking capacity at 400 V AC. UL 489 transformer protection. Screw/snap-on 35 mm DIN rail. S00 size. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","title":"3RV2811-0BD10","Height":"144 mm","Upwards":"70 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"70 mm","At The Side":"30 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for transformer protection with approval circuit breaker UL 489, CSA C22.2 No.5-02 A-release 0.2 A N-release 4.2 A screw terminal Standard switching capacity","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M4","Mounting Position":"any","Solid Or Stranded":"1 ... 10 mm², max. 2x 10 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 500 V rated value":"100 kA","at 690 V rated value":"100 kA","Design Of The Product":"For transformer protection according to UL 489/CSA C22.2 No.5","Ground Fault Detection":"No","Phase Failure Detection":"No","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.2 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.2 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.2 A","at AWG cables for main contacts":"2x (14 ... 10)","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"1 ... 16 mm², max. 6 + 16 mm²","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"2.5 ... 3 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","at 480 AC Y/277 V according to UL 489 rated value":"65 kA","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"4.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$69.85","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/61b188c6d003bacc4b18b5ec4ac7b804.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=97504&mlfb=3RV2811-0BD10"},"ai":{"faq":[{"question":"Will 3RV2811-0BD10 drop into a panel that was specified around 3RV2011-0AA10 without rewiring?","answer":"Yes. Both breakers share the same S00 frame, 45 mm width, 35 mm DIN rail mounting, and M4 screw terminals accepting 1 to 10 mm² conductors. The power connections and DIN rail footprint are identical."},{"question":"What compliance documentation does this brand provide for 3RV2811-0BD10?","answer":"The breaker is designed for transformer protection per UL 489 and CSA C22.2 No.5. Standard Siemens SIRIUS documentation includes RoHS and REACH declarations; the UL/CSA listing is the primary safety certification."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2811-0BD10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2811-0BD10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}