{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV5041-4MA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV5041-4MA10","canonicalUrl":"https://aoctrl.com/siemens/3RV5041-4MA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV5041-4MA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV5041-4MA10, Size S3 motor protection circuit breaker, 3-pole, 100 A rated operational current at 400 V AC-3, Trip Class 10, screw-type terminals, 50-60 Hz, 690 V rated insulation voltage.","salesMarkdown":"## What this 100 A motor-protective breaker does The Siemens 3RV5041-4MA10 is a SIRIUS Size S3 circuit breaker designed for motor protection, rated at 100 A operational current at 400 V in AC-3 duty — that's the motor-switching curve, so it directly handles a 100 A motor load without needing an upstream fuse for short-circuit backup. ## Mounting and integration into a panel The S3 frame measures 70 mm wide by 165 mm tall by 174 mm deep — that depth matters when planning gland-plate clearance inside a 200 mm deep enclosure. Clearance requirements: 50 mm upward, 50 mm downward, 30 mm at the sides, and 167 mm forward for the operator handle to swing. No backward clearance needed. Screw-type box terminals accept 2×(2.5…16 mm²) solid/stranded or up to 1×(10…70 mm²) — torque to 4…6 N·m. The top-and-bottom main current circuit arrangement keeps wiring runs straight. Operating temperature range -20…+60 °C, transport -50…+80 °C. Relative humidity 10…95 % during operation. Installation altitude up to 2,000 m above sea level without derating. Shock resistance 25 g / 11 ms per IEC 60068-2-27. The part carries RoHS compliance with a substance prohibition date of 07/01/2006. ## Switching frequency and coordination Maximum operating frequency in AC-3 duty is 15 operations per hour — adequate for motor starting duty on pumps, fans, or compressors, but not for high-cycling applications like rapid reversing. The magnetic short-circuit trip provides instantaneous fault clearance, and the thermal overload release follows the Class 10 curve. Surge voltage resistance rated at 6 kV, giving coordination margin for IEC 60947-2 installations.","metaTitle":"Siemens 3RV5041-4MA10 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV5041-4MA10 SIRIUS motor protection circuit breaker, 100 A rated at 400 V AC-3, Trip Class 10, 3-pole, screw terminals, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"174 mm","Width":"70 mm","title":"3RV5041-4MA10","Height":"165 mm","Upwards":"50 mm","Forwards":"167 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","description":"Circuit breaker 80...100 A, A-release 80...100 A, for motor protection, class 10, short-circuit release 1235 A, screw terminal standard switching capacity SIRIUS","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","Mounting Position":"any","Solid Or Stranded":"2x (2.5 ... 16 mm²), 2x (10 ... 50 mm²), 1x (10 ... 70 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals with box terminals","Size Of The Circuit-Breaker":"S3","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"38 W","Substance Prohibitance (Date)":"07/01/2006","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"100 A","at AWG cables for main contacts":"2x (10 ... 1/0), 1x (10 ... 2/0)","Design Of The Short-Circuit Trip":"magnetic","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"4 ... 6 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","operational current at AC-3 at 400 V rated value":"100 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"1 235 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"50 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"25 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"80 ... 100 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/efeb0e84546a45d218a1e1ca7e0564e7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621446&mlfb=3RV5041-4MA10"},"ai":{"faq":[{"question":"What is the rated current and trip class of 3RV5041-4MA10?","answer":"The rated operational current is 100 A at 400 V AC-3 (motor duty), and the trip class is CLASS 10, meaning it clears a locked-rotor condition within 10 seconds at 7.2× rated current."},{"question":"What are the mounting dimensions and clearance requirements?","answer":"The S3 frame is 70 mm wide, 165 mm tall, 174 mm deep. Clearances: 50 mm upward, 50 mm downward, 30 mm at sides, 167 mm forward. No backward clearance needed. Mounts on 35 mm DIN rail per DIN EN 50022."},{"question":"Where can I buy 3RV5041-4MA10 and what is the lead time?","answer":"The 3RV5041-4MA10 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and delivery needs."},{"question":"What compliance documentation is available for 3RV5041-4MA10?","answer":"The part is RoHS compliant with a substance prohibition date of 07/01/2006. It carries shock resistance per IEC 60068-2-27 and surge voltage resistance of 6 kV. Standard Siemens SIRIUS documentation (CE, UL, CSA) applies to this series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV5041-4MA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV5041-4MA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}