{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-0BA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-0BA15","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-0BA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-0BA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV6011-0BA15 motor protection circuit breaker, size S00, 3-pole, 0.2 A rated operational current, Class 10 thermal overload release, 690 V AC-3, screw terminals, snap-on DIN rail mount.","salesMarkdown":"The Siemens 3RV6011-0BA15 is a SIRIUS motor protection circuit breaker in the compact S00 frame, designed for protecting 3-phase motor circuits up to 0.2 A rated operational current. It combines a thermal overload release (Class 10 trip characteristic) with a magnetic short-circuit release in a single 45 mm wide, 3-pole device. The 0.2 A rating makes it suitable for fractional-horsepower motors, small pumps, fans, or conveyor drives where fine overload protection is needed. The S00 frame keeps panel depth to 96 mm, fitting tight enclosures where every millimeter counts. ## Trip class and protection coordination The magnetic short-circuit trip (fixed, non-adjustable) clears bolted faults instantly. Total power loss is 5 W typical at rated load, which matters for thermal budgeting in sealed, high-density panels. The 6 kV rated surge voltage resistance (impulse withstand) ensures coordination with upstream surge protection devices. For projects requiring REACH or UL documentation, the SIRIUS series typically provides declarations via Siemens Industry Online Support. Main and auxiliary circuits use screw-type terminals. Main contacts accept 2× (0.5 to 1.5 mm²) solid/stranded or 2× (0.75 to 2.5 mm²) — or 2× (18 to 12 AWG) / 2× (20 to 16 AWG). Auxiliary terminals take 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²), with AWG equivalents 2× (20 to 16) and 2× (18 to 14). Tightening torque for main contacts: 0.8 to 1.2 N·m. Clearance requirements: 50 mm upwards and downwards, 30 mm at the sides, 0 mm forwards and backwards — essential for arc-flash containment and heat dissipation in the panel layout.","metaTitle":"Siemens 3RV6011-0BA15 SIRIUS Motor Protection CB, 0.2 A, Cla","metaDescription":"Siemens 3RV6011-0BA15 SIRIUS motor protection circuit breaker, 0.2 A rated current, Class 10 trip, 690 V AC-3, 3-pole, size S00, DIN rail mount. Active production. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"5 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.2 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3 at 400 V rated value":"0.2 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"2.6 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","breaking capacity maximum short-circuit current (Icu) at AC at 400 V rated value":"100 kA","breaking capacity operating short-circuit current (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.14 ... 0.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621637&mlfb=3RV6011-0BA15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-0BA15/alternatives.json"},"ai":{"faq":[{"question":"What is the 3RV6011-0BA15 rated current and trip class?","answer":"Rated operational current is 0.2 A with a Class 10 thermal overload release, meaning it trips within 10 seconds at 7.2× rated current for motor locked-rotor protection."},{"question":"What are the mounting dimensions for the 3RV6011-0BA15?","answer":"Width 45 mm, height 97 mm, depth 96 mm. It snaps onto 35 mm DIN rail per DIN EN 60715 or can be screw-mounted. Clearance: 50 mm above/below, 30 mm sides."},{"question":"Where can I buy the 3RV6011-0BA15?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Does the 3RV6011-0BA15 drop into a panel designed for the 3RV6011-0CA10?","answer":"Both are SIRIUS size S00 breakers with the same 45 mm width and DIN rail mounting, so they share the same panel footprint and clearance requirements. The difference is the rated current — 0.2 A here versus the 0CA10's rating — so verify the motor FLA matches before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-0BA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-0BA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}