{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-0DA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-0DA10","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-0DA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-0DA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV6011-0DA10 motor protection circuit breaker, size S00, 0.32 A rated operational current, Class 10 trip, 690 V, 50/60 Hz, screw-type terminals, DIN-rail mount.","salesMarkdown":"The Siemens 3RV6011-0DA10 is a SIRIUS motor protection circuit breaker in the S00 frame size, rated at 0.32 A operational current with a Class 10 trip characteristic. It protects motors against overload (thermal release) and short-circuit (magnetic release) in a single device, sized for small fractional-horsepower loads on 50/60 Hz systems up to 690 V. The S00 footprint — 45 mm wide, 97 mm tall, 96 mm deep — fits standard panel layouts; clearance requirements are 50 mm above and below, 30 mm to the side, and zero forward/backward clearance needed. The 0.32 A AC-3 rating at 400 V is the motor-switching current — this breaker is sized for a very small motor (roughly 0.12 kW at 400 V three-phase). The 690 V rated insulation voltage covers most industrial supply voltages, and the 6 kV rated surge voltage resistance ensures coordination with typical distribution panels.","metaTitle":"Siemens 3RV6011-0DA10 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV6011-0DA10 SIRIUS motor protection circuit breaker, 0.32 A rated current, Class 10 trip, 690 V, 50/60 Hz, size S00, DIN-rail mount. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","title":"3RV6011-0DA10","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","description":"Circuit breaker 0.32 A A-release 0.22...0.32 A, N-release 4.2 A, for motor protection, class 10, screw connection, standard switching capacity","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"5 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.32 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","operational current at AC-3 at 400 V rated value":"0.32 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"4.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.22 ... 0.32 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/28b128e4485c18845283d51e7fffbc68.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621640&mlfb=3RV6011-0DA10"},"ai":{"faq":[{"question":"What is the closest functional alternative to 3RV6011-0DA10?","answer":"The 3RV6011-0CA10 is a direct peer in the same S00 frame and Class 10 trip, but with a different rated current — verify your motor's FLA before substituting. The 3RV6011-0DA10 drops into the same DIN-rail footprint and wiring scheme as the 3RV6011-0CA10 without panel modifications."},{"question":"Where can I buy 3RV6011-0DA10?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability."},{"question":"What compliance documentation does 3RV6011-0DA10 carry?","answer":"The part is RoHS compliant with a substance prohibition date of May 1, 2012. Additional compliance documentation (UL, IEC) is available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-0DA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-0DA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}