{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-0EA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-0EA15","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-0EA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-0EA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV6011-0EA15, Size S00 motor protection circuit breaker, 3-pole, 0.4 A rated operational current, Class 10 thermal-magnetic trip, 690 V AC, 50/60 Hz, screw terminals, snap-on DIN rail mount.","salesMarkdown":"It combines a thermal overload relay (Class 10) and a magnetic short-circuit release in one compact 45 mm wide housing. Rated at 0.4 A operational current on a 690 V AC, 50/60 Hz system, it provides coordinated motor branch protection in control panels. The 96 mm depth fits standard shallow enclosures; 45 mm width occupies one standard module slot. The 0.4 A rated operational current (at AC-3 duty, 690 V max) sets the motor FLA this breaker protects. AC-3 is the standard motor-switching category (squirrel-cage motors, starting and switching off during running). The operating frequency is capped at 15 switching cycles per hour — fine for typical pump or fan duty; not for high-cycling applications like rapid indexing. Total typical power loss is 5 W at rated current. Terminals accept 2× (0.5 to 1.5 mm²) solid/stranded or 2× (0.75 to 2.5 mm²) for the main circuit; auxiliary contacts use 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) finely stranded with ferrules. AWG equivalents: main 2× (18 to 12) or 2× (20 to 16); auxiliary 2× (20 to 16) or 2× (18 to 14). Torque for main screw terminals: 0.8 to 1.2 N·m. ## Panel Integration & Wiring Shock resistance: 25 g for 11 ms per IEC 60068-2-27.","metaTitle":"Siemens 3RV6011-0EA15 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV6011-0EA15 SIRIUS motor protection circuit breaker, 0.4 A rated current, Class 10 thermal-magnetic trip, 690 V AC, 50/60 Hz. Screw and snap-on DIN rail mount. Current li","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","title":"3RV6011-0EA15","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","description":"Circuit breaker 0.4 A A-release 0.28...0.4 A, N-release 5.2 A, for motor protection, class 10, screw connection, standard switching capacity, w. transverse AUX. switch 1 NO + 1 NC","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"5 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.4 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3 at 400 V rated value":"0.4 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"5.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.28 ... 0.4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7fc156379c7893f1256a66dab14a56dd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621643&mlfb=3RV6011-0EA15"},"ai":{"faq":[{"question":"When sourcing 3RV6011-0EA15, what's the closest functional second-source — 3RV1011-0GA10?","answer":"The 3RV1011-0GA10 is a peer in the same SIRUS motor protection breaker family but in the larger S0 frame size. The 3RV6011-0EA15 (S00 frame) is physically smaller — 45 mm wide vs the S0's wider footprint — and has a different mounting hole pattern. It will not drop into a panel wired for the S0 frame without a new DIN rail arrangement and possibly different terminal spacing. For a direct functional match, stay within the S00 frame; the 3RV1011 series is a different mechanical fit."},{"question":"What is 3RV6011-0EA15's listed depth (96 mm) on this component line?","answer":"The depth is 96 mm. Combined with the 45 mm width and 97 mm height, it fits standard shallow enclosures."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-0EA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-0EA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}