{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-0FA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-0FA15","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-0FA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-0FA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV6011-0FA15, size S00, 0.5 A rated current, Class 10, 3-pole, screw terminals, 690 V, 50/60 Hz.","salesMarkdown":"## SIRIUS size S00 motor protection circuit breaker — 0.5 A, Class 10 It carries a rated operational current of 0.5 A at 690 V AC-3, with a thermal overload release and a magnetic short-circuit trip. Three poles for the main current circuit, screw-type terminals accepting 2x (0.5 to 1.5 mm²) solid or 2x (0.75 to 2.5 mm²) stranded. The S00 frame keeps the width at 45 mm — a single module width on standard DIN rail, which matters when you are packing multiple feeders into a compact panel. ## Panel integration and clearances Clearance requirements: 50 mm upwards, 50 mm downwards, 30 mm to the side, zero forwards or backwards. That 50 mm above and below is the ventilation zone for the thermal bimetallic release — pack closer and you derate the trip curve. The S00 footprint (45 mm wide, 97 mm high, 96 mm deep) fits standard distribution boards and motor control centre buckets. Relative humidity 10 to 95 % during operation. Shock resistance 25g / 11 ms per IEC 60068-2-27. Substance prohibitance date 05/01/2012 — the part was RoHS-compliant well before the current RoHS 3 deadline. Surge voltage resistance rated 6 kV, which covers the impulse withstand requirement for most industrial control panels per IEC 60947-1.","metaTitle":"Siemens 3RV6011-0FA15 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV6011-0FA15 SIRIUS motor protection circuit breaker, 0.5 A rated operational current, Class 10 trip, 690 V, size S00. Available to order — confirm current pricing and ava","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"5 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.5 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3 at 400 V rated value":"0.5 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"6.5 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.35 ... 0.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4da4725df88c3eddb04da16660ce02b8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621645&mlfb=3RV6011-0FA15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-0FA15/alternatives.json"},"ai":{"faq":[{"question":"What is the rated current and voltage of 3RV6011-0FA15?","answer":"Rated operational current is 0.5 A at AC-3, with a maximum rated voltage of 690 V. Operating frequency 50 to 60 Hz."},{"question":"What is the frame size and mounting of 3RV6011-0FA15?","answer":"Size S00, 45 mm wide, snap-on mounting onto 35 mm DIN rail per DIN EN 60715. Any mounting position allowed."},{"question":"Will 3RV6011-0FA15 drop into a panel designed for 3RV1011-0GA10?","answer":"Both are size S00 Siemens SIRIUS breakers with the same 45 mm width and DIN-rail mounting, so the physical fit and panel cutout are identical. The key difference is the current rating — the 3RV6011-0FA15 is a 0.5 A unit, while the 3RV1011-0GA10 serves a different current range. Verify the motor FLA matches before substitution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-0FA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-0FA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}