{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-0KA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-0KA10","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-0KA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-0KA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV6011-0KA10, 3-pole, 1.25 A rated operational current, Class 10 thermal-magnetic trip, 690 V AC-3, screw terminals, size S00, for 35 mm DIN rail.","salesMarkdown":"Its 1.25 A rated operational current (AC-3 at 400 V) and thermal-magnetic overload release (Class 10) mean it protects small motors — fractional-horsepower pumps, fans, or conveyors — from sustained overload and short-circuit faults. The magnetic short-circuit trip clears hard faults fast, while the thermal element allows a brief inrush before tripping, matching motor start curves. Snap-on mounting onto 35 mm DIN rail per DIN EN 60715, with screw terminals for the main circuit (2x 0.75–2.5 mm² solid/stranded, or 2x 4 mm²).","metaTitle":"Siemens 3RV6011-0KA10 SIRIUS Motor Protection CB, 1.25 A, Cl","metaDescription":"Siemens 3RV6011-0KA10 SIRIUS motor protection circuit breaker, 1.25 A, Class 10 trip, 690 V, 3-pole, screw terminals, DIN rail mount. Active production, sourced to order. Request a","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"6 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1.25 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","operational current at AC-3 at 400 V rated value":"1.25 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"16 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.9 ... 1.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9b2eb18dd2687a8e4ef804f1d6bc3393.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621652&mlfb=3RV6011-0KA10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-0KA10/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the 3RV6011-0KA10?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Will 3RV6011-0KA10 drop into a panel specified for 3RV6011-0CA10 without rewiring?","answer":"Both are SIRIUS size S00 breakers with the same 45 mm width, 96 mm depth, and screw-terminal arrangement. The 3RV6011-0KA10 is a 1.25 A Class 10 unit; the 3RV6011-0CA10 carries a different current rating. Panel fit is identical, but verify the current setting matches the motor full-load amps before swapping."},{"question":"What compliance documentation does Siemens provide for 3RV6011-0KA10?","answer":"The part carries a substance prohibitance date of 05/01/2012, indicating RoHS compliance. Standard Siemens documentation includes the declaration of conformity and environmental compliance sheets."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-0KA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-0KA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}