{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-1BA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-1BA15","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-1BA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1BA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV6011-1BA15, size S00, 2 A rated operational current, Class 10 trip, 690 V, 45 mm wide, screw terminals.","salesMarkdown":"The Siemens 3RV6011-1BA15 is a SIRIUS motor protection circuit breaker in size S00, rated for 2 A operational current at 690 V AC-3. The magnetic short-circuit release handles fault clearing. At 45 mm wide and 96 mm deep, it fits standard panel layouts with 50 mm clearance required above and below for arc exhaust and wiring access. Screw-type terminals on both main and auxiliary circuits accept 2× (0.5 to 2.5 mm²) solid/stranded or 2× (18 to 12 AWG). The product is designed for motor protection with short-circuit protection function included. Relative humidity during operation spans 10 to 95 %. Shock resistance per IEC 60068-2-27 is 25g for 11 ms.","metaTitle":"Siemens 3RV6011-1BA15 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV6011-1BA15 SIRIUS motor protection circuit breaker, 2 A rated current, Class 10 trip, 690 V, size S00, 45 mm wide. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"6 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"2 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3 at 400 V rated value":"2 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"26 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.4 ... 2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3e22101fe2b2dd53d1000edd95e1e9d6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621257&mlfb=3RV6011-1BA15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1BA15/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3RV6011-1BA15?","answer":"The 3RV6011-0CA10 is a close functional peer within the same SIRIUS S00 frame size, but it carries a different rated current. Verify your motor FLA against the 3RV6011-0CA10's rating before substituting; the 3RV6011-1BA15 is set at 2 A. Both share the same Class 10 trip characteristic, 690 V rating, and 45 mm width, so they drop into the same DIN-rail footprint without rewiring the panel."},{"question":"Who supplies 3RV6011-1BA15 and how is it quoted?","answer":"This part is sourced through independent industrial automation distribution. It is quoted to order against an RFQ; availability and current pricing are confirmed at quote time. Volume inquiries are welcome."},{"question":"What compliance documentation does Siemens provide for 3RV6011-1BA15?","answer":"The product carries a RoHS compliance date of 05/01/2012. It is designed to meet IEC standards for motor protection circuit breakers, including surge voltage resistance of 6 kV and shock resistance per IEC 60068-2-27. Standard Siemens documentation includes the declaration of conformity and technical data sheet."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-1BA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-1BA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}