{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-1DA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-1DA10","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-1DA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1DA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV6011-1DA10, motor-protection circuit breaker, size S00, 3.2 A, Class 10, 690 V, 50/60 Hz, screw terminals, DIN-rail mount.","salesMarkdown":"## Motor-protection circuit breaker, 3.2 A, Class 10 The Siemens SIRIUS 3RV6011-1DA10 is a motor-protection circuit breaker in the S00 frame size, rated 3.2 A operational current at AC-3 / 400 V with a thermal-magnetic trip characteristic (Class 10). It handles 690 V maximum at AC-3 and operates at 50/60 Hz. The 3.2 A rating means it directly protects a motor drawing that full-load current — the Class 10 trip ensures the overload release opens within 10 seconds at 7.2× Ie, matching standard induction-motor starting profiles for pumps, fans, and light conveyors. The S00 footprint — 45 mm wide, 97 mm tall, 96 mm deep — fits standard 45 mm modular spacing; plan for 50 mm clearance above and below for wiring access and heat dissipation. Screw-type terminals on top and bottom accept 2×(0.75–2.5 mm²) solid/stranded or 2×4 mm², torqued to 0.8–1.2 N·m.","metaTitle":"Siemens 3RV6011-1DA10 SIRIUS Motor Protection CB, 3.2 A, Cla","metaDescription":"Siemens 3RV6011-1DA10 SIRIUS motor-protection circuit breaker, 3.2 A rated current, Class 10 trip, 690 V, 50/60 Hz, size S00, DIN-rail mount. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"6 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"3.2 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","operational current at AC-3 at 400 V rated value":"3.2 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"42 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.2 ... 3.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dcf1b88027d63a0420cf84c660d7c27e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621260&mlfb=3RV6011-1DA10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1DA10/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RV6011-1DA10?","answer":"Submit an RFQ through the storefront. This part is sourced to order through independent distribution; pricing and stock levels are confirmed at quote time."},{"question":"What compliance documentation does the 3RV6011-1DA10 carry?","answer":"RoHS compliance is documented with a substance-prohibition date of May 1, 2012. The part is designed for motor-protection duty per IEC/EN 60947 standards; screw terminals and DIN-rail mount are standard."},{"question":"What is the 3RV6011-1DA10's depth on the DIN rail?","answer":"96 mm deep, with 50 mm clearance required above and below for wiring and airflow."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-1DA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-1DA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}