{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-1DA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-1DA15","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-1DA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1DA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor-protection circuit breaker, size S00, 3.2 A rated operational current, Class 10 thermal-magnetic overload and short-circuit trip, 690 V AC-3, screw terminals, snap-on 35 mm DIN rail.","salesMarkdown":"## SIRIUS 3RV6011-1DA15 — Motor-Protection Circuit Breaker, 3.2 A, Class 10 The Siemens 3RV6011-1DA15 is a SIRIUS motor-protection circuit breaker in the compact S00 frame, rated at 3.2 A operational current with a Class 10 thermal-magnetic trip curve. That means it protects standard induction motors up to roughly 1.5 kW at 400 V, tripping fast enough on overload to keep the winding insulation intact during a stalled-rotor or jam condition — the Class 10 curve clears within 10 seconds at 7.2x Ie. The magnetic short-circuit release handles fault clearing without relying on an upstream fuse, which simplifies the panel bill of materials. Clearance requirements are 50 mm upward and downward, 30 mm to the side, and zero forward or backward — so you can pack it tight against the back panel. ## Integration & Wiring Main circuit terminals accept 2x (0.5 to 1.5 mm²) solid/stranded or 2x (0.75 to 2.5 mm²) finely stranded with ferrules; AWG equivalents are 2x (18 to 12) for the main contacts. Auxiliary and control circuit terminals use the same screw-type design, with AWG 2x (20 to 16) or 2x (18 to 14). Torque the main contact screws to 0.8 to 1.2 N·m. The auxiliary switch is transverse-mounted, which means it occupies the same width footprint — no extra DIN space needed for a side-mount block. Rated operational frequency for AC-3 motor switching is 15 operations per hour maximum — adequate for a pump or fan start/stop cycle, but not for high-duty jogging or reversing service. Power dissipation is 6 W typical, so derating within an enclosed panel is minimal at this current level.","metaTitle":"Siemens 3RV6011-1DA15 SIRIUS Motor Protection CB, 3.2 A, Cla","metaDescription":"Siemens 3RV6011-1DA15 SIRIUS motor-protection circuit breaker, 3.2 A rated, Class 10 thermal-magnetic trip, 690 V AC-3, screw terminals, snap-on 35 mm DIN rail. Current lifecycle s","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"6 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"3.2 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3 at 400 V rated value":"3.2 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"42 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","breaking capacity maximum short-circuit current (Icu) at AC at 400 V rated value":"100 kA","breaking capacity operating short-circuit current (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.2 ... 3.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621261&mlfb=3RV6011-1DA15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1DA15/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV6011-1DA15 and how do I get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate."},{"question":"What is 3RV6011-1DA15's listed depth?","answer":"The depth is 96 mm. Combined with a width of 45 mm and height of 97 mm, it fits the S00 frame size for compact DIN-rail mounting."},{"question":"Will 3RV6011-1DA15 drop into a panel specified around 3RV6011-0CA10 without rewiring?","answer":"Both are S00-frame SIRIUS motor-protection breakers with the same mounting footprint and screw-terminal pattern, so mechanical fit is identical. The key difference is the current rating: 3RV6011-1DA15 is 3.2 A, while 3RV6011-0CA10 is a different rating — verify the motor full-load amps before swapping. If the rating matches, no rewiring is needed."},{"question":"What compliance documentation does Siemens provide for 3RV6011-1DA15?","answer":"The part carries a substance prohibition date of 05/01/2012, indicating RoHS compliance. Standard Siemens documentation includes the declaration of conformity and CE marking; check the specific product documentation for UL and IEC certifications relevant to your jurisdiction."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-1DA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-1DA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}